{"product_id":"fluke-1662-multifunction-tester-flu1662","title":"Fluke 1662 Multifunction Tester FLU1662","description":"\u003cp\u003eThe Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On\/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures RCD switching time and tripping level (ramp test)\u003c\/li\u003e\n\u003cli\u003eMeasures trip time and current for RCD type A \u0026amp; AC in one test\u003c\/li\u003e\n\u003cli\u003eMeasures RCD variable current\u003c\/li\u003e\n\u003cli\u003eProvides automatic RCD test sequence\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003eIncludes a phase sequence indicator\u003c\/li\u003e\n\u003cli\u003eComes with hard carrying case, padded carrying and waist strap, and remote control probe and lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAC voltage measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy 45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.8% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e360 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e660 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eContinuity testing (RLO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (autoranging)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation resistance measurement (RISO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy of test voltage (at rated test current)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+10%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 MΩ \/ 50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLoop and line impedance (ZI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eProspective earth fault current, PSC test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 A \/ 10 kA (50 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 A \/ 0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRCD testing, RCD types tested\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCD Type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA\u003csup\u003e4\u003c\/sup\u003e, AC¹, G², S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTripping speed test (ΔT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent settings¹\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplier\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003eRCD Type G\u003c\/td\u003e\n\u003ctd\u003e310 ms\u003cbr\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCD Type S\u003c\/td\u003e\n\u003ctd\u003e510 ms\u003cbr\u003e160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30% to 110% of RCD rated current¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% of IΔN²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDwell time\u003c\/td\u003e\n\u003ctd\u003eType G\u003c\/td\u003e\n\u003ctd\u003e300 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType S\u003c\/td\u003e\n\u003ctd\u003e500 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified trip current ranges (EN 61008-1)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePhase Sequence Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcon\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\" alt=\"icon phase sequence indicator\" align=\"top\"\u003e\n\u003cp\u003e Phase Sequence indicator is active.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 x 25 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.3 (kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eType AA, 6 ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with EN\/IEC 61010-1 and  EN\/IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT III \/ 500V; CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN61557-1 to EN61557-7 and EN61557-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899091607731,"sku":"834120","price":2538.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/86db63f6-f9fb-44e9-8d75-b108002eb9c0_product_slideshow_main2x.webp?v=1787725334","url":"https:\/\/beyondtools.com\/en-ca\/products\/fluke-1662-multifunction-tester-flu1662","provider":"Beyond Tools","version":"1.0","type":"link"}