{"title":"Fluke","description":"","products":[{"product_id":"60-600v-non-contact-voltage-tester-led-flashlight-lvd2-by-fluke","title":"60-600V Non-Contact Voltage Tester \u0026 LED Flashlight LVD2 by Fluke","description":"\u003cp\u003eLVD2 volt light, offered by Fluke combines a non-contact AC voltage detector and LED flashlight into one easy to use pen-style design. It features dual sensitivity detection, turning blue from 1\" to 5\" (2.54 cm to 12.7 cm) from the source and red when at the source. The LVD2 is a CAT IV 600 V rated and is suitable for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact AC voltage tester and LED flashlight\u003c\/li\u003e\n\u003cli\u003eDetects from 90 to 600 V AC\u003c\/li\u003e\n\u003cli\u003eFeatures dual-sensitivity for two levels of detection\u003c\/li\u003e\n\u003cli\u003eIndicates proximity to AC voltage source with blue light\u003c\/li\u003e\n\u003cli\u003eIndicates you're at the source with red light\u003c\/li\u003e\n\u003cli\u003eUltra-bright white LED light with 100,000-hour bulb life\u003c\/li\u003e\n\u003cli\u003eSafety rated to CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eOperating temperature 0 °C to 50 °C\u003c\/li\u003e\n\u003cli\u003eAAA battery included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-details\"\u003e\n\u003cdiv class=\"std-equip-text\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794565603507,"sku":"200206","price":111.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/LVD2..jpg?v=1741807060"},{"product_id":"90-1000v-non-contact-voltage-tester-1ac-ii-by-fluke","title":"Fluke 90-1000V Non-Contact Voltage Tester FLU1AC-A1-11","description":"\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe pocket-sized voltage detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe portable 1AC II non-contact voltage tester from Fluke are easy to use – just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there's voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home and even detect miswires of an electrical outlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe tip glows red and a beeper sounds when voltage is detected\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA loud, easy to hear beeper will sound and the tip will glow red when voltage is detected\u003c\/li\u003e\n\u003cli\u003eOptionally, the beeper can be disabled for use in quiet environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous self-test so you always know it’s working\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the tip blinks red you know it’s working properly\u003c\/li\u003e\n\u003cli\u003eProvides a continual visual indication that the 1AC II is on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e90 V to 1000 V AC or 200 V to 1000 V AC voltage detection range for wide application use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWide voltage detection range allows for use in a broad range of applications\u003c\/li\u003e\n\u003cli\u003eAlso available in a low voltage model from 20 V to 90 V AC for controls circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated to CAT IV 1000 V for added protection\u003c\/li\u003e\n\u003cli\u003eCE and CSA approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional tool features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudible\/Silent mode for added convenience in quiet environments\u003c\/li\u003e\n\u003cli\u003eOn\/Off button\u003c\/li\u003e\n\u003cli\u003eBatteries included\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBe aware of voltage easily - the tip glows red and a beeper sounds when voltage is detected\u003c\/li\u003e\n\u003cli\u003eContinuous self-test so you always know it's working\u003c\/li\u003e\n\u003cli\u003eVoltage detection range for wide application use - 90 V to 1000 V AC or 200 V to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eAudible\/Silent mode for added convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"std-equip-text\"\u003e\n\u003cbr\u003e\u003cstrong\u003eTechnical Data:-\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.fluke.com\/en-au\/product\/electrical-testing\/basic-testers\/fluke-1ac-ii#\" target=\"_blank\"\u003eView Product Manual Here.\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794615279795,"sku":"8729347","price":119.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/REPVS.jpg?v=1741783540"},{"product_id":"alligator-clip-set-ac175-by-fluke","title":"Fluke Alligator Clip Set AC175","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulated alligator clips with flexible boots\u003c\/li\u003e\n\u003cli\u003eThreaded shaft to twist onto test probes\u003c\/li\u003e\n\u003cli\u003eJaw opening: 7mm (0.275\")\u003c\/li\u003e\n\u003cli\u003eJaw contact material: nickel-plated steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eModular clips are used with modular test leads to offer additional flexibility to configure your leads to your individual needs. The insulated alligator clip jaws provide a 7 mm opening with flexible boots. The Fluke AC175 Threaded Alligator Clip Set comes with a one-year warranty and a cat rating of CAT III 1000 V, CAT IV 600 V, 10 A. This alligator clip set has slide-on alligator clips (red, black) compatible with multiple Fluke test probes: Fluke TL71 Premium Test Lead Set Fluke TL75 Hard Point™ Test Lead Set Fluke TL175 TwistGuard™ Test Leads Fluke TP175 TwistGuard™ Test Probes\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794623799475,"sku":"8001737","price":88.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/AC175.jpg?v=1741777343"},{"product_id":"electrical-tester-voltage-continuity-and-current-tester-t5-1000-by-fluke","title":"Electrical Tester - Voltage, Continuity and Current Tester T5-1000 by Fluke","description":"\u003cdiv id=\"keyfeature_content\"\u003e\n\n\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cdiv id=\"keyfeature_content\"\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eOpenJaw design: measure current without breaking the circuit\u003c\/li\u003e\n\n \t\u003cli\u003eTester automatically selects AC or DC voltage, up to 1000 V\u003c\/li\u003e\n\n \t\u003cli\u003eWork in tight spaces with detachable Slim Reach probe tips\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\n\nMeasure current up to 100 A without breaking the circuit with OpenJaw design. The T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. Use it to check voltage, continuity, and currentâ€“all with one compact tool.\n\n\n\nHow to use the T5-1000\n\n\u003cul\u003e\n\n \t\u003cli\u003eJust select volts, ohms, or current and the tester does the rest. The electrical tester auto-selects between AC and DC voltage up to 1000 V.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nPlus, the OpenJaw design allows for fast and easy current measurements without needing to make metallic contact, just slide a wire into the open fork. The continuity beeper offers a quick go\/no-go tests, resistance measurements to 1000 Î©.\n\n\n\nThe electrical tester comes with detachable Slim Reach probe tips so you can easily work in tight spaces. Or hand free work when you use the test lead holder to make the meter an 'extended handle\" for the probe.\n\n\n\nKey safety features\n\n\u003cul\u003e\n\n \t\u003cli\u003eAn integrated protection circuit allows the tester to stay connected to a voltage source longer than a solenoid tester. The T5-1000 Electrical Tester also boasts:\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nA CAT III 1000V, CAT IV 600 V rating\n\n\n\nWithstands a 10 ft. (3 m) drop.\n\n\n\nThe T5-1000 has and Auto-off mode to conserve battery life. The unit fits into an optional holster that attaches to a belt and neatly stows test leads.\n\n\n\nFluke T5-1000 vs T6-1000\n\n\n\nThe T5-1000 uses the OpenJaw design to measure current without metallic contact, just slide the wire in the open fork and the T5 will do the rest. It also measures voltage and continuity with the test leads. The T6-1000 (https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/basic-testers\/fluke-t6-1000) is designed to use FieldSense technology to display both current and voltage simultaneously.\n\n\n\n'This is a very good meter and I trust my life with it almost every day\" - Kevin\n\n\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794654240947,"sku":"8001723","price":399.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/T5-1000.jpg?v=1741760124"},{"product_id":"electrical-tester-fluke-t5-600-by-fluke","title":"Electrical Tester Fluke T5-600 by Fluke","description":"\u003cdiv id=\"keyfeature_content\"\u003e\n\n\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cdiv id=\"keyfeature_content\"\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eMeasure current up to 100 A without breaking the circuit\u003c\/li\u003e\n\n \t\u003cli\u003eMeter automatically selects AC or DC voltage, up to 600 V\u003c\/li\u003e\n\n \t\u003cli\u003eResistance measurements up to 1000 Î© plus continuity test\u003c\/li\u003e\n\n \t\u003cli\u003eWork in tight spaces with detachable SlimReach probe tips\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\n\nThe T5-600 Electrical Tester is a versatile troubleshooting tool you can carry to every job site. Use it to check voltage, continuity, and current, all with one compact, rugged tool. Just select volts, ohms, or current and the tester does the rest. For higher voltage applications check out the Fluke T5-1000.\n\n\n\n'\u003cem\u003eThis meter is perfect for my use as I do HVAC and Electrical work, and this will give me what I need for troubleshooting and performance of equipment.\u003c\/em\u003e\" - Paul\n\n\n\n\u003cstrong\u003eMeasure current up to 100 A without breaking the circuit with OpenJaw design\u003c\/strong\u003e\n\n\n\nThe trendsetting OpenJaw design allows for fast and easy current measurement, safely and without metallic contact to a live conductor. The integrated protection circuit allows it to stay connected to a voltage source longer than a solenoid tester would be able to. The T5-600 is also designed to:\n\n\u003cul\u003e\n\n \t\u003cli\u003eWithstand a 10 ft. (3 m) drop\u003c\/li\u003e\n\n \t\u003cli\u003eConserve battery life with auto-off mode\u003c\/li\u003e\n\n \t\u003cli\u003eFit in one hand with handy probe storage in the back of the holster\u003c\/li\u003e\n\n \t\u003cli\u003eAccept Fluke accessory test clips with the test leads\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cstrong\u003eMeter automatically selects AC or DC voltage for tests up to 600 V\u003c\/strong\u003e\n\n\n\nVoltage tests are faster and easier than ever before. Just turn the knob to voltage (V) and place your leads on the test points. The T5-600 auto-selects either AC or DC voltage, depending on what is detected. This meter is suitable for both residential or commercial applications and is designed to keep you safe with a CAT III 600 V rating.\n\n\n\n\u003cstrong\u003eFieldSense Information\u003c\/strong\u003e\n\n\n\nLearn how to use the T5:\n\n\n\n\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/T6______qreng0200.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload the Quick Reference Guide\u003c\/a\u003e\n\n\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6009799_6118_ENG_A_W.PDF\" target=\"_blank\" rel=\"noopener\"\u003eDownload the T5 \"How-To\" Demonstration Guide\u003c\/a\u003e\n\n\u003ca href=\"https:\/\/content.fluke.com\/products\/t6\/en\/fieldsense-proving-unit\/demo-guide.html\" target=\"_blank\" rel=\"noopener\"\u003eRead the FieldSense Proving Unit Demonstration Guide\u003c\/a\u003e\n\n\n\n\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/T6______qreng0200.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003c\/a\u003e\n\n\n\n\u003cstrong\u003eT6 Electrical Tester Helps Team at Cutting Edge Cancer Research Center\u003c\/strong\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/players.brightcove.net\/5229431846001\/default_default\/index.html?videoId=5785630676001\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794654273715,"sku":"8001722","price":339.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/T5-600.jpg?v=1741760227"},{"product_id":"electricians-digital-multimeter-with-non-contact-voltage-fluke-117-by-fluke","title":"Fluke Electrician's Digital Multimeter with Non Contact Voltage Fluke 117","description":"\u003cdiv id=\"keyfeature_content\"\u003e\n\n\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eCompact, true-rms digital multimeter for electricians\u003c\/li\u003e\n\n \t\u003cli\u003eIncludes multimeter, 4mm silicone test leads, holster and manual\u003c\/li\u003e\n\n \t\u003cli\u003eIntegrated non-contact voltage detection keeps you safe\u003c\/li\u003e\n\n \t\u003cli\u003ePrevent false readings from ghost voltage with selectable low-impedance mode\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nThe Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:\n\n\u003cul\u003e\n\n \t\u003cli\u003eResistance\u003c\/li\u003e\n\n \t\u003cli\u003eContinuity\u003c\/li\u003e\n\n \t\u003cli\u003eFrequency\u003c\/li\u003e\n\n \t\u003cli\u003eCapacitance\u003c\/li\u003e\n\n \t\u003cli\u003eMin\/Max\/Average\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cstrong\u003eFor the everyday\u003c\/strong\u003e\n\n\n\nA digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:\n\n\u003cul\u003e\n\n \t\u003cli\u003eCommercial buildings\u003c\/li\u003e\n\n \t\u003cli\u003eHospitals\u003c\/li\u003e\n\n \t\u003cli\u003eSchools\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cstrong\u003eNon-contact voltage detection\u003c\/strong\u003e\n\n\n\nKeep yourself safer with integrated VoltAlert™ technology. Fast, go\/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.Automatic AC\/DC selection\n\n\n\nSet the dial and get your measurement quickly with AutoVolt. This automatic AC\/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.Frequently asked questions\n\n\n\n\u003cstrong\u003eWhat is the difference between the Fluke 115 and the Fluke 117?\u003c\/strong\u003eWhile similar, the Fluke 115 and the Fluke 117 meters are designed for slightly different purposes. The Fluke 115 is a compact true-rms digital multimeter that's great for field service. The Fluke 117 is a designed specifically for electricians. With a quick turn of the dial both units provide measurements for:\n\n\u003cul\u003e\n\n \t\u003cli\u003eResistance\u003c\/li\u003e\n\n \t\u003cli\u003eContinuity\u003c\/li\u003e\n\n \t\u003cli\u003eFrequency\u003c\/li\u003e\n\n \t\u003cli\u003eCapacitance\u003c\/li\u003e\n\n \t\u003cli\u003eMin\/Max\/Average\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nThe Fluke 117 offers non-contact voltage detection and has a selectable low-impedance mode to prevent false readings from ghost voltage. The 117 also features automatic selection of AC or DC voltage, depending on what was detected.\u003cstrong\u003eDoes the Fluke 117 read milliamps?\u003c\/strong\u003eThe Fluke 117 Electrician's Multimeter includes a 10 amp current range for making both AC or DC current measurements. The maximum resolution is 1 milliamp.\u003cstrong\u003eHow do you use a Fluke 117 True-rms multimeter?\u003c\/strong\u003e\n\n\n\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794654306483,"sku":"8001713","price":490.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/FLU117-1.jpg?v=1741759766"},{"product_id":"electricians-digital-multimeter-thermometer-true-rms-fluke-179-by-fluke","title":"Electrician's Digital Multimeter Thermometer True-RMS Fluke 179 by Fluke","description":"\u003cdiv id=\"keyfeature_content\"\u003e\n\n\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003e1000V AC\/DC; 10A AC\/DC (with test leads and current jacks); resistance to 50 Mâ„¦; capacitance to 10,000 Î¼F, frequency to 100 kHz; temperature from -40 â„ƒ to 400 â„ƒ\u003c\/li\u003e\n\n \t\u003cli\u003eRobust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min\/Max-Average recording\u003c\/li\u003e\n\n \t\u003cli\u003eBacklit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\n\nThe Fluke 179 True-rms Digital Multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. This incredibly versatile multimeter makes a perfect front-line troubleshooting tool with an input protection rating of CAT III 1000 V, CAT IV 600 V. The built-in temperature measurement with the included thermocouple, analog bar graph and backlit digital display make it easier to take the measurements you need.\n\n\n\n\u003cstrong\u003eA full set of basic and advanced troubleshooting capabilities including:\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eManual and automatic ranging\u003c\/li\u003e\n\n \t\u003cli\u003eDisplay Hold and Auto Hold\u003c\/li\u003e\n\n \t\u003cli\u003eMin\/Max-Average recording\u003c\/li\u003e\n\n \t\u003cli\u003eVoltage measurements to 1000 V AC or DC\u003c\/li\u003e\n\n \t\u003cli\u003eCurrent measurements to 10 A AC\/DC\u003c\/li\u003e\n\n \t\u003cli\u003eResistance to 50 Mâ„¦; capacitance to 10,000 Î¼F, frequency to 100 kHz; temperature from -40 â„ƒ to 400 â„ƒ\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nAll of these features come paired with a lifetime warranty. DC current measurements. The maximum resolution is 1 milliamp.\u003cstrong\u003eHow do you use a Fluke 117 True-rms multimeter?\u003c\/strong\u003e\n\n\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794654404787,"sku":"8001714","price":899.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/FLU179.jpg?v=1741760005"},{"product_id":"hard-pointa-c-test-lead-set-tl75-by-fluke","title":"Hard Point Test Lead Set TL75 by Fluke","description":"\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eTest lead and probe in one unit\u003c\/li\u003e\n\n \t\u003cli\u003e48 inches (1.22 meter) long\u003c\/li\u003e\n\n \t\u003cli\u003eCAT II 1000 V, 10 A rated\u003c\/li\u003e\n\n \t\u003cli\u003eCAT IV 600 V, CAT III 1000 V rated with protective cap\u003c\/li\u003e\n\n \t\u003cli\u003eCSA Listed\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nThe Fluke TL75 Hard Point™ Test Leads are a set of comfort grip, PVC-insulated probes. TL75s offer the convenience of a test lead and probe together in one unit with a variety of connections. This set of test leads are recommended for all general-purpose measurements and are compatible with a wide range of Fluke meters and tools.\n\n\n\nDesigned for safety:-\n\n\n\nThe Fluke TL75 Hard Point™ Test Lead Set is CAT II 1000 V, 10 A rated. When the protective caps are placed on the leads, the ratings jump up to CAT IV 600 V, CAT III 1000 V.\n\n\n\nCompatible with Fluke alligator clips:-\n\n\n\nExpand your measurement capabilities with special adapters to your TL75 set. Add alligator clips or adapters to accomplish even more:\n\n\u003cul\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/accessories\/test-leads\/ac175\"\u003eFluke AC175 Alligator Clip Set\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/accessories\/adapters\/fluke-tp920\"\u003eTP920 Test Probe Adapter Set\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794669379763,"sku":"8100215","price":66.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/TL75.jpg?v=1741752402"},{"product_id":"insulation-multimeter-1587fc-by-fluke","title":"Fluke Insulation Multimeter 1587FC","description":"\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\n\u003cdiv id=\"product-overview\"\u003e\n\n\u003cdiv id=\"overview_content\"\u003e\n\n\n\n\u003cb\u003eKeep yourself safe. Find hidden problems faster. Put the paperwork down.\u003c\/b\u003e\n\n\n\nFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\n\n\n\n\u003cstrong\u003eAdd diagnostics with Fluke Connect\u003c\/strong\u003e\n\n\n\nThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect ® Measurements app to your smartphone and gain additional functions, including:\n\n\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eSafety first. Keep yourself out of harm's way by monitoring your test measurements remotely.\u003c\/li\u003e\n\n \t\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\n \t\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\n \t\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\n \t\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\n \t\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\n \t\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect ® Assets (sold separately)\u003c\/li\u003e\n\n \t\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\n \t\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\n \t\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\n \t\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect ® Assets (sold separately)\u003c\/li\u003e\n\n \t\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\n \t\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\n \t\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\n \t\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\n \t\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\n \t\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794674491571,"sku":"8001725","price":2255.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/FLU1587FC.jpg?v=1741749967"},{"product_id":"large-soft-case-for-dmms-c25-by-fluke","title":"Fluke Large Soft Case for DMMs C25","description":"Protect your Fluke meters with Fluke's most popular zippered carrying case sold to date. This durable case is made with a high-quality polyester exterior and features padding on the interior pocket.\n\n\n\nIf you're looking for a Fluke case for meters like your 117, 115 or for your 87V, the C25 is designed for those multimeters. It is recommended to be used with most mid-sized multimeters, process and temperature meters. Some meters this Fluke case is compatible with:\n\n\u003cul\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-323\"\u003eFluke 323 True RMS Clamp Meter\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-324\"\u003eFluke 324 True-RMS Clamp Meter with Temperature \u0026amp; Capacitance\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/digital-multimeters\/87v-imsk\"\u003eFluke 87V IMSK Industrial Multimeter Service Combo Kit\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/digital-multimeters\/fluke-114\"\u003eFluke 114 Electrical Multimeter\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/digital-multimeters\/fluke-115\"\u003eFluke 115 Field Technicians Digital Multimeter\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/digital-multimeters\/fluke-116\"\u003eFluke 116 Digital HVAC Multimeter\u003c\/a\u003e\u003c\/li\u003e\n\n \t\u003cli\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/digital-multimeters\/fluke-117\"\u003eFluke 117 Electrician's Multimeter with Non-Contact Voltage\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cblockquote\u003e\"...ample room for the quick reference card, the meter, and the leads (...) the material quality and construction should take abuse while protecting your expensive meter\"- Jabit, verified customer\u003c\/blockquote\u003e\n\n\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eZippered carrying case with padding and inside pocket\u003c\/li\u003e\n\n \t\u003cli\u003eDimensions 218 x 128 x 64 mm (8.6 x 5 x 2.52 in)\u003c\/li\u003e\n\n \t\u003cli\u003eConvenient belt loop for hands-free carrying\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794680455347,"sku":"8001734","price":119.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/C-25.jpg?v=1741736125"},{"product_id":"non-contact-infrared-thermometer-30adegc-to-500adegc-62-max-by-fluke","title":"Fluke Mini Infrared Thermometer 62 MAX","description":"\u003cp\u003eThe Fluke 62 MAX Infrared thermometer delivers many of the features of the Fluke 62 MAX+, but features a single laser and 10:1 distance to spot ratio. You can use the Fluke 62 MAX to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents. It is small in size and extremely easy to use. The single laser helps you pinpoint the target for more accurate readings and makes it easier to measure temperatures in hard to reach areas. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX to deliver accurate, repeatable temperature measurements, rain or shine, in even the dirtiest and dustiest industrial sites. And it’s rugged enough to take a 3-meter drop so no worries even if you work from a ladder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low alarms for rapid detection of temperatures outside the limits\u003c\/li\u003e\n\u003cli\u003ePowered by a single, standard AA battery.\u003c\/li\u003e\n\u003cli\u003eComes with a three-year warranty -30-\u003c\/li\u003e\n\u003cli\u003eWithstands a 3 m (9.8 ft.) drop\u003c\/li\u003e\n\u003cli\u003eOffers small, lightweight form factor to clip comfortably to your tool belt or belt loop, or easily fit in your tool box\u003c\/li\u003e\n\u003cli\u003eFeatures a large, backlit display to make data easier to read, even in dark areas.\u003c\/li\u003e\n\u003cli\u003eDisplays Min\/Max\/Avg\/Dif: the minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHelpful hints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-au\/learn\/blog\/temperature\/infrared-thermometers-electrical-industrial-and-hvac-applications\"\u003eInfrared thermometers: electrical, industrial, and HVAC applications\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-au\/learn\/blog\/temperature\/how-to-get-great-results-with-an-infrared-thermometer\"\u003eHow to get great results with an infrared thermometer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 529.032px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 165.14%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e-30°C to 500°C (-22°F to 932°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 58.7812px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 58.7812px;\"\u003e±1.5°C or ±1.5% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e10:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e±0.8% of reading or \u0026lt; ±1.0°C (2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e10 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 165.14%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 19.5938px;\"\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 19.5938px;\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.5698%; height: 39.1875px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 132.57%; height: 39.1875px;\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794700673203,"sku":"8001724","price":289.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/62-MAX.jpg?v=1741733527"},{"product_id":"tpak-toolpaka-c-magnetic-meter-hanger-tpak-by-fluke","title":"TPAK ToolPak Magnetic Meter Hanger TPAK by Fluke","description":"\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\n\n\u003cul\u003e\n\n \t\u003cli\u003eStrong, rare-earth magnet hanger strap with Fluke durability\u003c\/li\u003e\n\n \t\u003cli\u003eHang with magnet or hook strap for non-magnetic surfaces\u003c\/li\u003e\n\n \t\u003cli\u003eSolves any hanging and positioning problem you may face\u003c\/li\u003e\n\n \t\u003cli\u003eEasily work hands-free\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nThe Fluke TPAK ToolPak™ Magnetic Meter Hanger allows you to hang your meter on nails, hooks, and pipes so you can take hands-free measurements. Always demand the best; use the original TPAK Meter hanging kit with its unique rare-earth magnet for superior gripping strength to ensure your tools don't slide or fall.\n\n\n\nHanging options for any jobsite:-\n\n\n\nHang your meter in a variety of ways for convenient hands-free operation, solve any hanging and positioning problems you may face. Use the hook and loop strap to wrap around a pole or pipe and hang your meter. Use the magnet to throw your meter on a panel door while you work the test leads to take a measurement quickly and safely.","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794746220723,"sku":"8100216","price":132.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/TPAK.jpg?v=1741707940"},{"product_id":"true-rms-ac-dc-clamp-meter-374fc-by-fluke","title":"True-RMS AC\/DC Clamp Meter 374FC by Fluke","description":"\u003cp\u003eFluke 374 FC delivers advanced troubleshooting performance and wireless connectivity:- The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex ® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Î©. Use wireless connectivity to keep a safe distance:- The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls. Versatile feature set:- With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:-\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced clamp meter that transmits measurements to your smartphone via Fluke Connect ® for viewing at a safer distance\u003c\/li\u003e\n\u003cli\u003ePerforms AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 6000 â„¦ with continuity detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 @ 600 A Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A (â‰¤ 600 A) 1 A (â‰¤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3% ±5 digits (5 â€“ 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cb\u003eDistance from Optimum\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eError\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eB\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (â‰¤600.0 V) 1 V (â‰¤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V (â‰¤600.0 V) 1 V (â‰¤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6000 Î©\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Î© (â‰¤600 Î©) 1 Î© (â‰¤6000 Î©)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 Î¼F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Î¼F (â‰¤ 100 Î¼F) 1 Î¼ F (â‰¤ 1000 Î¼F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity - non-condensing (\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eâ‰¤90% RH (at 10 °C to 30 °C) â‰¤75% RH (at 30 °C to 40 °C) â‰¤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length (head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V IEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794748678323,"sku":"8001733","price":789.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/374FC.jpg?v=1741717240"},{"product_id":"twistguarda-c-test-leads-tl175-by-fluke","title":"Fluke TwistGuard Test Leads TL175","description":"Twist. Test. Stay Safe.\n\n\n\nThe Fluke TL175 TwistGuard Test Leads offer adjustable length test tips for use in different measurement environments. By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm (0.75 in to 0.16 in).\n\n\n\n'\u003cem\u003eThey work well, are very durable, and add a whole new level to safetyâ€¦along with the ability to twist them to expose the entire probe for more traditional feel while testing\u003c\/em\u003e\"- S.C., verified customer\n\n\n\nPatented TwistGuard extendable tip\n\n\n\nThe adjustable tip shroud meets new electrical safety requirements to reduce tip exposure while providing the versatility needed for most measurements. The correct category rating for the tip exposure being used is always visible on the test leads. This makes the TL175 test leads suitable for use in many environments:\n\n\u003cul\u003e\n\n \t\u003cli\u003eCAT II 1000 V\u003c\/li\u003e\n\n \t\u003cli\u003eCAT III 1000 V\u003c\/li\u003e\n\n \t\u003cli\u003eCAT IV 600 V\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\nSafety inside and out\n\n\n\nWearGuard lead wire wear indicator makes it easier to see insulation wear and tear. If the inner, white insulation layer shows through the outer, black layer, damage is indicated, and the leads must be replaced. The silicone insulation withstands high temperatures and remains flexible in cold temperatures. While the universal input plugs are compatible with all instruments that accept standard 4 mm shrouded banana plugs.","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41794750021811,"sku":"8001736","price":98.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/TL175.jpg?v=1741707086"},{"product_id":"installation-multifunction-tester-1664-fc-by-fluke","title":"Installation Multifunction Tester 1664 FC by Fluke","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMultifunction tester that tests to all local regulations\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes \"Insulation Pre-test\" that detects when appliances are connected to the system and stops the test\u003c\/li\u003e\n\u003cli\u003eRuns seven installation tests automatically in one sequence with a single connection through Auto Test\u003c\/li\u003e\n\u003cli\u003eAllows you to share test results in real time over your smartphone via Fluke Connect Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 1664 FC Multifunction Installation Tester helps expedite installations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1664 FC puts a lot of testing power in your hands to quickly and efficiently test to all local regulations, protect appliances, and share test results in real time over your smartphone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtect appliances from accidental damage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1664 FC is the only tester with \"Insulation PreTest\" that stops the insulation test and provides a visual warning if it detects that an appliance is connected to the system under test. This helps you avoid potentially serious and costly mistakes that can cause damage to your customers’ peripheral equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Test reduces test time\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAuto Test performs up to seven installation tests in one sequence, ensuring compliance with local installation regulations. This reduces the number of manual connections, thus decreasing the possibility of errors and reducing test time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSave time and enhance collaboration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 1664 FC is Fluke Connect®-enabled, you can send test results to your smartphone, save them to the cloud, and share measurements in real time with team members through a ShareLive video call. It's the fastest way to let your team see what you see, and to help you get approvals without leaving the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRetrieve stored results from anywhere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke Cloud™ storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. You get world-class data protection and you can import the data into Fluke DMS (Data Management Software) to process and generate certificates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther helpful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompact, lightweight (less than 1.3 kg) with padded neck-strap to free your hands\u003c\/li\u003e\n\u003cli\u003eRotary dial knob clearly indicates which function is selected, all in one spot with no complex multi-level menus.\u003c\/li\u003e\n\u003cli\u003eOffers additional high current loop mode for faster measurements than loop tests with non-trip mode for RCDs\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003ePerforms fast voltage measurement between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections\u003c\/li\u003e\n\u003cli\u003eMeasures RCD trip current and trip time in parallel (RCD type AC and A)\u003c\/li\u003e\n\u003cli\u003eMeasures PEFC or PSC and loop impedance in parallel and displays them together on the dual display\u003c\/li\u003e\n\u003cli\u003eOffers ring testing so you can select the required input sockets with soft keys and not have to exchange test leads\u003c\/li\u003e\n\u003cli\u003eUses continuity test currents to measure motor windings\u003c\/li\u003e\n\u003cli\u003eDetects raised earth voltages \u0026gt; 50 V with Earth Volt Touchpad, indicating potential dangerous situations\u003c\/li\u003e\n\u003cli\u003eFeatures large display with backlight, clear symbols, and exceptionally wide viewing angle for easy and safe readings\u003c\/li\u003e\n\u003cli\u003eOffers extended three-layer memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-details\"\u003e\n\u003cdiv class=\"std-equip-text\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":42175651578035,"sku":"8300632","price":4985.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/1664FC.jpg?v=1741638041"},{"product_id":"hard-point-test-lead-set-as400-by-fluke","title":"Probe Accessory Extension Set 1 AS400 by Fluke","description":"","brand":"Fluke","offers":[{"title":"Default Title","offer_id":42350342308019,"sku":"8730520","price":240.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/AS400.png?v=1741628799"},{"product_id":"installation-multifunction-tester-1663fvs-by-fluke","title":"Fluke Installation Multifunction Tester FLU1663\/FVF","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull featured tester for installation professionals\u003c\/li\u003e\n\u003cli\u003eTests to all local regulations and provides test results for complete documentation\u003c\/li\u003e\n\u003cli\u003eTests continuity at L-N, N-PE inputs\u003c\/li\u003e\n\u003cli\u003eTests smooth dc sensitive RCDs (Type B)\u003c\/li\u003e\n\u003cli\u003eTests earth resistance, voltage, and frequency\u003c\/li\u003e\n\u003cli\u003eOffers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 1663 Multifunction Installation Tester is the ideal choice for hard working professionals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1663 installation tester delivers the full-featured functionality and advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. Operation is intuitive and easily mastered by all levels of workers so you can put it to work immediately for quick and efficient testing to all local regulations. Additional helpful features like On\/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChecks wiring polarity to detect broken N wires\u003c\/li\u003e\n\u003cli\u003eMeasures insulation resistance and loop and line resistance\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003eMeasures motor windings with continuity test\u003c\/li\u003e\n\u003cli\u003eCalculates prospective earth fault current (PEFC\/IK) and prospective short-circuit current (PSC\/IK)\u003c\/li\u003e\n\u003cli\u003eMeasures RCD switching time and tripping level (ramp test)\u003c\/li\u003e\n\u003cli\u003eMeasures trip time and current for RCD type A \u0026amp; AC in one test\u003c\/li\u003e\n\u003cli\u003eMeasures RCD variable current\u003c\/li\u003e\n\u003cli\u003eProvides automatic RCD test sequence\u003c\/li\u003e\n\u003cli\u003eIncludes a phase sequence indicator\u003c\/li\u003e\n\u003cli\u003eSafety rated CAT III 500V, CAT IV 300V\u003c\/li\u003e\n\u003cli\u003eComes with hard carrying case, padded carrying and waist strap, and remote control probe and lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications: Fluke 1663 Multifunction Testers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 541px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eAC voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eAccuracy 45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.8% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e360 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e660 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eContinuity testing (RLO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRange (autoranging)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e\u0026gt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eInsulation resistance measurement (RISO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e50-100-250-500-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eAccuracy of tTest voltage (at rated test current)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e+10%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eInsulation resistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e20 MΩ \/50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eLoop and line impedance (ZI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eProspective earth fault current, PSC test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e1000 A \/ 10 kA (50 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e1 A \/ 0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eComputation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eRCD testing, RCD types tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRCD Type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eAC¹\u003cbr\u003eG²,S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eModel 1663\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eA\u003csup\u003e4\u003c\/sup\u003e, AC¹, G²,S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eTripping speed test (ΔT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eCurrent settings¹\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eMultiplier\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 164.49px;\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd style=\"width: 153.51px;\"\u003eRCD Type G\u003c\/td\u003e\n\u003ctd style=\"width: 203px;\"\u003e310 ms\u003cbr\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153.51px;\"\u003eRCD Type S\u003c\/td\u003e\n\u003ctd style=\"width: 203px;\"\u003e510 ms\u003cbr\u003e160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e30% to 110% of RCD rated current¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eStep size\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e10% of IΔN²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 164.49px;\"\u003eDwell time\u003c\/td\u003e\n\u003ctd style=\"width: 153.51px;\"\u003eType G\u003c\/td\u003e\n\u003ctd style=\"width: 203px;\"\u003e300 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153.51px;\"\u003eType S\u003c\/td\u003e\n\u003ctd style=\"width: 203px;\"\u003e500 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eSpecified trip current ranges (EN 61008-1)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eEarth Resistance Test (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e0.1 Ω \/ 1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003ePhase Sequence Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eIcon\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e\n\u003cimg align=\"top\" alt=\"icon phase sequence indicator\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\"\u003e Phase Sequence indicator is active.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 521px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e10 x 25 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003e1.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eType AA, 6 ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eComplies with EN\/IEC 61010-1 and EN\/IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003eOvervoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eCAT III \/ 500V; CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 164.49px;\"\u003ePerformance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356.51px;\"\u003eEN61557-1 to EN61557-7 and EN61557-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv class=\"product-details\"\u003e\n\u003cdiv class=\"std-equip-text\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":42377295986867,"sku":"1000366","price":3729.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/products\/fluke_1663_multifunction_installation_tester-1500x1000-1.jpg?v=1741604721"},{"product_id":"microscanner™-cable-verifier-series-flums2100-by-fluke","title":"MicroScanner² Cable Verifier Series FLUMS2100 by Fluke","description":"\u003cp\u003eThe MicroScanner2 Cable Verifier presents a revolutionary change in voice, data, and video cable testing. It starts by taking results from what was four different test modes and displaying them all at once - graphical wiremap, pair lengths, distance to fault, cable ID, and far end device. What's more, its integrated RJ11, RJ45, and coax test ports support virtually any type of low voltage cable testing with no need for awkward adapters. The end result is reduced test time and technician error. That makes high-quality installations more efficient than ever.\u003cbr\u003eToday's communications technicians have a lot more problems to deal with than just the cabling. They have to rule out a whole host of potential cable and service issues before determining the cause of a connection problem. Is there telephone voltage? What's the polarity? Is there an Ethernet switch at the far end? Is PoE available? MicroScanner2 acknowledges this, giving technicians high power vision to verify today's most common voice, data, and video services. That means faster, more comprehensive troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTests all common media types including RJ11, RJ45, Coax, with no need for adapters\u003c\/li\u003e\n\u003cli\u003eLocates virtually any cable or wire pair with IntelliTone digital and analog toning\u003c\/li\u003e\n\u003cli\u003eRevolutionary interface - Graphical wiremap, length, cable ID, and distance to fault displayed on one screen\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":42819721232563,"sku":"8043036","price":1535.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/FNET-MS2-100-1500x1000-1.jpg?v=1741399839"},{"product_id":"electricians-digital-multimeter-thermometer-true-rms-fluke-179-by-fluke-1","title":"Electronics Multimeter and Deluxe Accessory Kit FLU179\/EDA2 by Fluke","description":"\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFluke 179 Digital Multimeter and EDA2 Accessories Kit\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003eIndustrial electricians work in tough environments. That's why the Fluke 179 True-rms Digital Multimeter is combined with an industrial-strength test lead probe kit in a compact lightweight soft case.\u003c\/div\u003e\n\u003cdiv itemprop=\"description\"\u003e\n\u003cstrong\u003eHeavy-duty electrical service\u003c\/strong\u003eThe Fluke 179 True-rms digital multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. The included 80BK-A Integrated digital multimeter temperature probe eliminates the need to carry a separate thermometer. You can hang your meter where it’s easy to see with the TPAK ToolPak™ Magnetic Meter Hanger, included in the kit. The C35 soft carry case that keeps everything ready to take with you includes three SureGrip™ accessories\n\u003cul\u003e\n\u003cli\u003eTL224 Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eAC280 Hook Clips\u003c\/li\u003e\n\u003cli\u003eTL910 Electronic Test Probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe right measurement functions\u003c\/strong\u003e\u003c\/p\u003e\nThe 179 is a true-rms multimeter, providing accurate measurements up to:\n\u003cul\u003e\n\u003cli\u003e1000 V ac\/dc;\u003c\/li\u003e\n\u003cli\u003e10 A ac\/dc;\u003c\/li\u003e\n\u003cli\u003eResistance to 50 MΩ;\u003c\/li\u003e\n\u003cli\u003eCapacitance to 10,000 μF,\u003c\/li\u003e\n\u003cli\u003eFrequency to 100 kHz;\u003c\/li\u003e\n\u003cli\u003eTemperature from -40 °C to 400 °C (-40 °F to 752 °F).\u003c\/li\u003e\n\u003c\/ul\u003e\nThe meter offers both manual and automatic ranging, Display Hold, Auto Hold, and Min\/Max-Average recording. The large backlit digital display is easy to in dark areas and includes an analog bar graph to view trending or unstable signals.\u003c\/div\u003e\n\u003cdiv itemprop=\"description\"\u003e\u003c\/div\u003e\n\u003cdiv itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA full-featured, precision multimeter for troubleshooting electrical and electronic systems\u003c\/li\u003e\n\u003cli\u003eDelivers accurate true-rms ac current and voltage plus frequency, capacitance, resistance, continuity and diode measurements\u003c\/li\u003e\n\u003cli\u003eSureGrip™ test leads, test probes and alligator clips\u003c\/li\u003e\n\u003cli\u003eIncludes ToolPak magnetic meter-hanger for easy viewing when using two hand to make measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv itemprop=\"description\"\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv itemprop=\"description\"\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 179 Multimeter\u003c\/li\u003e\n\u003cli\u003e80BK-A Integrated DMM Temperature Probe\u003c\/li\u003e\n\u003cli\u003eInstalled 9V battery\u003c\/li\u003e\n\u003cli\u003eUsers’ manual\u003c\/li\u003e\n\u003cli\u003eAC280 SureGrip™ Hook Clips\u003c\/li\u003e\n\u003cli\u003eTL910 Electronic Test Probes\u003c\/li\u003e\n\u003cli\u003eTL224 SureGrip™ Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003eSoft carry case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43657077653683,"sku":"834119","price":919.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/FLU179EDA2_2.jpg?v=1741179340"},{"product_id":"200a-600v-multimeter-kit-with-holster-t6-h6-1ackit-by-fluke","title":"200A 600V Multimeter Kit with Holster T6-H6-1ACKIT by Fluke","description":"\u003cp\u003eMeasure voltage up to 1000V AC through the open fork, without test lead contact to live voltage, opening covers or removing wire nuts. Works with wires up to AWG 4\/0 (120 mm²), carrying as much as 200A.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for AC voltage, current \u0026amp; freq measurement without making electrical contact to live voltage\u003c\/li\u003e\n\u003cli\u003eSimultaneous voltage \u0026amp; current display shows all power supply measurements at a glance for efficient troubleshooting\u003c\/li\u003e\n\u003cli\u003e1 to 1000V AC or DC\u003c\/li\u003e\n\u003cli\u003e0.1 to 200A AC\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 100 kΩ\u003c\/li\u003e\n\u003cli\u003eFrequency measurement 45 Hz to 66 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43657637167283,"sku":"9000657","price":669.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/T6-H6-1ACKIT.jpg?v=1741187963"},{"product_id":"industrial-master-test-lead-set-flutlk289-by-fluke","title":"Industrial Master Test Lead Set FLUTLK289 by Fluke","description":"\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke TLK289 - Industrial Master Test Lead Set is designed for electrical and electronics testing in today’s industrial environment. Fluke test leads, alligator clips and test probes broaden the ability to take meter measurements, extending the capabilities of your meter. They are an integral part of the complete measurement system, helping to get accurate readings while remaining safe. Includes 8 items.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL224 Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC220 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eAC280 SureGrip™ Hook Clips\u003c\/li\u003e\n\u003cli\u003e80BK-A Integrated DMM Temperature Probe\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak Magnetic Hanger\u003c\/li\u003e\n\u003cli\u003eC116 Soft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":43657761226931,"sku":"9304390","price":415.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/FLUTLK289.jpg?v=1741187841"},{"product_id":"fluke-networks-linkiq™-duo-cable-network-wi-fi-tester","title":"Fluke Networks LinkIQ™ Duo Cable+Network+Wi-Fi Tester","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCable performance testing to 10GBASE-T plus wire map, TDR\u003c\/li\u003e\n\u003cli\u003eSwitch IP address, name, port \/ VLAN number, data rates + ping\u003c\/li\u003e\n\u003cli\u003eDetect and test PoE power under load to Class 8\u003c\/li\u003e\n\u003cli\u003eWi-Fi analysis to Wi-Fi 6E: networks, channels, and access points\u003c\/li\u003e\n\u003cli\u003eManage results and print reports from LinkWare™ PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe LinkIQ™ Cable+Wi-Fi+Network Tester is the testing solution to verify cable performance up to 10 Gb\/s and solve network connectivity problems. The LinkIQ tester validates cable performance using frequency-based measurements and a wire map of the cable under test. It also performs ping tests to verify connectivity and nearest switch diagnostics to identify key network issues and validate switch configuration - eliminating the need for another device. The LinkIQ Duo model adds Wi-Fi analysis to Wi-Fi 6E (where approved), including networks, channels, and access points plus warning of common configuration issues. The IE models allow identification of miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables supporting EtherNet\/IP, PROFINET, EtherCAT and other Industrial Ethernet protocols. Additional features include Analog and Digital Toning, Port Blink, Remote Office Locators, and the ability to manage results via LinkWare™ PC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eValidates Cable Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLinkIQ ensures that tested links meet performance requirements. It can measure lengths up to 1,000 feet (305 m) and provide distance to faults such as opens, shorts, and unterminated cable. The included remote ID provides a complete wire map of the cable pairs to identify miswired and split pairs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetailed Ping Tests Speed Troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLinkIQ performs IP ping tests that verify connectivity and provides nearest switch diagnostics, including advertised data rate (up to 10GBASE-T), half\/full duplex identification, switch name and IP address, port number, VLAN information, and load test up to Class 8 (90 W). With LinkIQ, you can quickly identify key network issues and validate switch configuration without having to use another device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn-Depth Testing for PoE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo simplify PoE installation and troubleshooting, LinkIQ displays the pairs where power is provided, showing the different power levels and pairs for dual-signature implementations. LinkIQ performs load testing up to Class 8 (90 W) by placing a load on the connection to ensure that the advertised power is actually being delivered across the cabling infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTesting to Wi-Fi 6E (LinkIQ Duo)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LinkIQ Duo tester makes it easy to understand the Wi-Fi environment by running a complete suite of tests and displaying the results the way you want to view them: by networks, channels, or access points. Choosing a specific item (such as an access point listed under a specific network) changes seamlessly to that view. The LinkIQ Duo tester also flags common configuration errors including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003euse of an illegal channel for the detected region\u003c\/li\u003e\n\u003cli\u003euse of a non-recommended channel\u003c\/li\u003e\n\u003cli\u003eaccess points that overlap with an adjacent access point unless one is low power\u003c\/li\u003e\n\u003cli\u003eweak security settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLinkIQ has a large, gesture-based touchscreen that displays a great deal of information and provides clear, easy-to-use controls such as sliders and a full keyboard. Its simplified TEST function displays results according to what’s plugged into the unit’s single RJ-45 connector. A single USB-C port provides connectivity to your PC for software updates, reporting, and charging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated with LinkWare PC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLinkIQ provides complete documentation via LinkWare PC. Up to 1,000 results with descriptive names can be stored in the tester and recalled. Test names and numbers automatically increment when saved (“Annex B-1,” “Annex B-2,” “Annex B-3,” etc.), saving valuable time when you test cables in sequence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple-language interface support: English, German, French, Japanese, Thai, Spanish, Traditional Chinese, Simplified Chinese, Korean, Russian, Italian, Portuguese\u003c\/li\u003e\n\u003cli\u003eCable Toning (compatible with the Fluke Networks IntelliTone™ Probe or Pro3000™)\u003c\/li\u003e\n\u003cli\u003eBlink Port light on switch\u003c\/li\u003e\n\u003cli\u003eCompatible with MicroScanner™ PoE Remote Identifiers\u003c\/li\u003e\n\u003cli\u003eColor touchscreen\u003c\/li\u003e\n\u003cli\u003eRechargeable Li-Ion battery via standard USB-C port\u003c\/li\u003e\n\u003cli\u003eEasy upgrades through USB-C or LinkWare PC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44577300938931,"sku":"8043715","price":6889.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/Fn-LinkIQ-Duo-01a.jpg?v=1762744464"},{"product_id":"fluke-meter-case-with-hard-sealed-lid-lift-out-tray-cl1600","title":"Fluke Meter Case with Hard Sealed Lid + Lift Out Tray CL1600","description":"\u003cp\u003eFluke Meter Case with Hard Sealed Lid + Lift Out Tray CL1600\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDeep interior to hold and protect your gear and accessories\u003c\/li\u003e\n\u003cli\u003eRubber gasket in lid seals out dust and keeps contents dry\u003c\/li\u003e\n\u003cli\u003eTop compartment for easy access to small parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe C1600 is a heavy duty, moulded-plastic case designed to carry your Fluke digital multimeters, process calibrators, and the accessories that go with them. The case features a snap-open lid compartment for easy access to small parts such as fuses, batteries, probes, and leads. Once opened, the case has a top storage compartment and a secondary bottom area for larger tools. The whole case can also be locked and easy to carry around with the large handle. You also get five hook-and-loop straps to wrap your cords and test leads along with the case.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44663680303283,"sku":"8043726","price":179.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/F_c1600_1500x1000_3d0b7de8-c8f5-4946-a765-ac49f9c0de13.jpg?v=1762742307"},{"product_id":"fluke-325-true-rms-clamp-meter","title":"Fluke 325 True RMS Clamp Meter AC\/DC 600V, 400A AC\/DC, True-RMS, with Temperature \u0026 Frequency","description":"\u003cp\u003eThe best general troubleshooting True-RMS clamp meters for commercial and residential use\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-rms AC\/DC current, voltage, temperature, frequency\u003c\/li\u003e\n\u003cli\u003eClamp meter, test leads, K-type thermocouple and soft case\u003c\/li\u003e\n\u003cli\u003eVersatile tool performs most front-line measurement tasks\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 325 True RMS Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch3\u003eTroubleshoot problems safely and accurately\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 325 True-rms Clamp Meter is a reliable, versatile troubleshooting tool for commercial and residential electricians. Featuring a slim design for easy transport and use, and a large display for efficient troubleshooting. In addition to true-rms AC current and voltage on non-linear loads, the 325 measures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC current\u003c\/li\u003e\n\u003cli\u003eDC voltage\u003c\/li\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ll carry fewer tools in your bag and get more work done.\u003c\/p\u003e\n\u003ch3\u003eCovers most problems you see day-in, day-out\u003c\/h3\u003e\n\u003cp\u003eThe 325 gives you a strong combination of measurement functions, in a tool that is reliable, easy-to-use and affordable. This clamp meter offers True-rms AC voltage and current measurements on non-linear signals. Paired with the CAT III 600 V, CAT IV 300 V safety rating the clamp meter can also measure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC current up to 400 A through jaw\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage to 600 V using test leads\u003c\/li\u003e\n\u003cli\u003eMeasures frequency from 5 Hz to 500 Hz; resistance to 40 kΩ\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -10 °C to 400 °C with included K-type thermocouple\u003c\/li\u003e\n\u003cli\u003eMin\/Max function records important values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44663683580083,"sku":"834162","price":479.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/f-325-01c-1500x1000.jpg?v=1762742309"},{"product_id":"fluke-digital-hvac-multimeter-fluke-116","title":"Fluke Digital HVAC Multimeter Fluke 116","description":"\u003cdiv id=\"keyfeature_content\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eDigital multimeter designed specifically for HVAC professionals\u003c\/li\u003e\n\u003cli\u003eIncludes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)\u003c\/li\u003e\n\u003cli\u003eProvides microamps to test flame sensors\u003c\/li\u003e\n\u003cli\u003eFeatures low input impedance to helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003ePresents a large white LED backlight for working in poorly lit areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures resistance, continuity, frequency, and capacitance\u003c\/li\u003e\n\u003cli\u003eProvides Min\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eComes with a holster with probe holders for easy storage\u003c\/li\u003e\n\u003cli\u003eFeatures a compact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eFits into optional ToolPak™ magnetic hanger for hands-free operation\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL75 test lead set\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature probe\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9 V battery\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications: Fluke 116 Digital HVAC Multimeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to + 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to + 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z Capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature²\u003cbr\u003e(Type-K thermocouple)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 400°C \/ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 10²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e-40°F to 752°F \/ 0.2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 18²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC μA true-rms (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC μamps\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 Hz\u003cbr\u003e50.00 kHz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e4. Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44909778895027,"sku":"1041810","price":635.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/FLU116_01__63467.1736219771.png?v=1762744660"},{"product_id":"fluke-ac-dc-proving-unit-prv240","title":"Fluke AC\/DC Proving Unit PRV240","description":"\u003cp\u003eThe Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique because it sources stable AC and DC voltages for both LoZ and HiZ instruments.\u003c\/p\u003e\n\u003cp\u003eThe Fluke PRV240 provides a safe method to verify that your electrical test tool is operating properly before and after you conduct any live tests. The concept of “Test Before Touch” (TBT) involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly through the actual measurement.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cp\u003eA single LED on the PRV240 indicates functionality, making this unit a simple-to-use solution for complying with TBT verification of your test tool. Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLong battery life—5,000 tests per set of four AA batteries\u003c\/li\u003e\n\u003cli\u003eIncludes TPak™ Magnetic Hanging Strap\u003c\/li\u003e\n\u003cli\u003eDesigned for safety and compliance\u003c\/li\u003e\n\u003cli\u003eValidate test tool functionality outside of hazardous zones\u003c\/li\u003e\n\u003cli\u003eSupplies 240 V, both DC and AC\u003c\/li\u003e\n\u003cli\u003eCompatible with both high or low impedance test tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing the PRV240 reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification of your tester or multimeter, so a TBT is performed. PPE is still needed for absence of voltage testing when appropriate.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45566441160883,"sku":"834163","price":370.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/9fcc16a2-818b-4841-9cea-b108002f25d0_product_slideshow_main2x.webp?v=1781164253"},{"product_id":"fluke-spare-battery-pack-ti-sbp3","title":"Fluke Spare Battery Pack TI-SBP3","description":"\u003cp\u003e\u003cspan\u003eExtra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBattery Type: Lithium-ion, 7.4 V, 19 Whr\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLED Display: 5-segment LED display to show charge level\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDimensions: 124 mm x 58.4 mm x 42.4 mm (4.9 in x 2.3 in x 1.7 in)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery Charge Time: 2.5 hours to full charge\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating Temperature: -20 °C to 50 °C (-4 °F to 122 °F)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStorage Temperature: -20 °C to 50 °C (-4 °F to 122 °F)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCharging Temperature: 0 °C to 40 °C (32 °F to 104 °F)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHumidity Range: 0% to 95%, non-condensing\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUN\/DOT Transportation: The Lithium ion battery pack meets the requirements of UN \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTests and Criteria Manual, Part III, Subparagraph 38.3.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568574554291,"sku":"8730711","price":435.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/FLK-TI-SBP3.webp?v=1781159915"},{"product_id":"fluke-multifunction-process-calibrator-725","title":"Fluke Multifunction Process Calibrator 725","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eWith the \u003cstrong\u003eFluke 725 Multifunction Process Calibrator\u003c\/strong\u003e, you can easily source and measure almost any process parameter and test almost any process device. Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. You can also perform both temperature and pressure transmitter calibrations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFrom the moment you pick it up, the Fluke 725 is ready to perform as a powerful, yet easy-to-use field calibrator. Its simple controls, without menus, make operation easy and the backlit display provides better visibility in poor light. It features a small, streamlined shape and a rugged, reliable design that makes it ideal for standing up to harsh field conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile troubleshooting tool\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower transmitters during test using the loop supply with simultaneous mA measurement so you can test a transmitter out of circuit and better isolate problems. The 725 can also test a variety of fast pulsed RTD transmitters and PLCs (Programmable logic controllers), with pulses as short as 10 ms.\u003c\/p\u003e\n\u003cp\u003eSource mA with simultaneous pressure measurement to conduct valve and I\/P (Input current\/Output pressure) tests in a single device. You can also test flow meters with frequency and CPM (counts per minute) functions and perform fast linearity tests with auto-step and auto-ramp features so you can quickly verify the mA signal at different output levels.\u003c\/p\u003e\n\u003cp\u003eFor more precision, pulse sourcing, and pulse counting (totalizing), consider the Fluke 726 Precision Multifunction Calibrator.\u003c\/p\u003e\n\u003cp\u003eFor documenting and HART communication built into your calibrator, consider the Fluke 754 Documenting Process Calibrator with HART.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"e0d78979c35b28872bf5deaa4d4462091\"\u003eEasily source and measure process parameters\u003c\/li\u003e\n\u003cli data-list-item-id=\"ebf6807541a7525797b7478eb35bf1ee5\"\u003eCalibrate temperature and pressure transmitters\u003c\/li\u003e\n\u003cli data-list-item-id=\"e1679a05849af15b1c9abf4c5bdaaa3d1\"\u003eMeasure and source mA, Volts DC, frequency, and resistance\u003c\/li\u003e\n\u003cli data-list-item-id=\"e95b43c985604f559451b03100dda824d\"\u003eBuilt-in 24 V loop power supply\u003c\/li\u003e\n\u003cli data-list-item-id=\"e25cb3d2fc635ec4a8ade8a96274437a5\"\u003eStore and recall frequently used calibration set ups\u003c\/li\u003e\n\u003cli data-list-item-id=\"e724bee87492c751e6a5d39102fdf255c\"\u003eSimple controls and backlit display make it easy-of-use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 23.5747%;\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e30.000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts (upper display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e30.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts (lower display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e100.00 mV\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e24.000 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 23.5747%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e0.0 to 400.0 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e401 to 1500 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.5 Ω (4-wire), 1 Ω (2- and 3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1500 to 3200 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1 Ω (4-wire), 1.5 Ω (2- and 3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 23.5747%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.05% + 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1.0 to 1100.0 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.05% + 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1.00 to 10.00 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.05% + 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1 V peak-to-peak-minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003eAccuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eSource Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 23.5747%;\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e100.00 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e10.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 23.5747%;\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e24.000 mA (source)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e24.000 mA (simulate)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.02% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 23.5747%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e15.0 to 400.0 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e401 to 1500 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.5 Ω (excitation current 0.05 to 0.8 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1500 to 3200 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1 Ω (excitation current 0.05 to 0.4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 23.5747%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1.0 to 1100.0 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e1.00 to 10.00 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eWaveform\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e5 V p-p squarewave, -0.1 V offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eRTDs and Thermocouples\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"21\" style=\"width: 23.5747%;\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003eNI-120\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.33°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (393)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (JIS)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-200 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-500 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-1000 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eJ\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eK\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eT\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eE\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eR\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eS\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eL\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eU\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eN\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003eJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eXK\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eBP\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"22\" style=\"width: 23.5747%;\"\u003eSource accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003eNI-120\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.33°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (393)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-100 (JIS)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-200 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-500 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003ePT-1000 (385)\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\" style=\"width: 75.7033%;\"\u003eAccuracy stated for 4-wire measurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eJ\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eK\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eT\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eE\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eR\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eS\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eL\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.7°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eU\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eN\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003eJ, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eXK\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e0.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eBP\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e1.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 23.5747%;\"\u003eRamp functions\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eRamps\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003eSlow ramp, Fast ramp, 25% step-ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 23.5747%;\"\u003eLoop power function\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eMaximum current\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e22 mA, short circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 23.5747%;\"\u003eStep functions\u003c\/td\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 18.6636%;\"\u003eSteps\u003c\/td\u003e\n\u003ctd style=\"width: 57.0397%;\"\u003e25% of range, 100% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e-20°C to 71°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003eEN 61010-1:1993, ANSI\/ISA S82.01-1994; CAN\/CSA C22.2 No 1010.1:1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e130 x 236 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eBattery replacement\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003eSeparate battery compartment, accessible without breaking calibration seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.5747%;\"\u003eSide port connections\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.7033%;\"\u003ePressure module connector, also used for remote real-time programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/media.fluke.com\/efbe10a1-294c-4cb1-8ec5-b3d10146561d_original%20file.pdf\"\u003eDownload the product data sheet here\u003c\/a\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568578945203,"sku":"87434499","price":6821.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/69b6b79e-ff4b-40dd-845b-b108002edaac_product_slideshow_main2x.webp?v=1781164230"},{"product_id":"fluke-documenting-process-hart-calibrator-754","title":"Fluke Documenting Process HART Calibrator 754","description":"\u003cp\u003eMaximize your investment\u003cspan\u003e \u003c\/span\u003ewith the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFluke 754 Documenting Process Calibrator-HART\u003c\/strong\u003e—a portable, rugged, and versatile calibrator trusted by professionals worldwide. Whether you’re calibrating instruments, troubleshooting, or performing routine maintenance, the Fluke 754 helps you work faster and more efficiently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose the Fluke 754?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-function capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSource, simulate, and measure pressure, temperature, and electrical signals—all in one handheld tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated HART communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibrate and maintain HART smart transmitters and instrumentation without a separate communicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBright dual display:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eView sourced and measured parameters at the same time for faster, error-free work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong battery life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRechargeable Li-Ion battery delivers up to 10 hours of operation, plus direct AC power support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless documentation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomate calibration procedures, store results, and ensure compliance with ISO 9000, FDA, EPA, and OSHA standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable and rugged:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Measurement and Source Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC\/DC voltage\u003c\/li\u003e\n\u003cli\u003emA loop with 24V loop power\u003c\/li\u003e\n\u003cli\u003ePressure (compatible with Fluke 750P Series Pressure Modules)\u003c\/li\u003e\n\u003cli\u003eThermocouples \u0026amp; RTDs\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eResistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Process Calibration. Simplified.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 754 is more than just a calibrator. Its built-in HART interface lets you perform nearly all digital communicator tasks. Easily handle fast-pulsed RTD transmitters and PLCs, custom auto-step and ramping, custom units, programmable measurement delay, and one- or two-point switch testing—all with one device.\u003c\/p\u003e\n\u003cp\u003eDownload procedures, lists, and instructions created in your calibration management software, or upload calibration results for documentation and analysis. The Fluke 754 supports a full week of procedures and is compatible with leading asset management solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGo Paperless with Fluke DPCTrack2 Software\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor a seamless, paperless calibration management experience, pair your Fluke 754 Documenting Process Calibrator-HART with Fluke DPCTrack2 Calibration Management Software. Simplify record-keeping, automate procedures, and streamline compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReady to Work Smarter? Upgrade to the Fluke 754 Today.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExperience the power, precision, and reliability of the Fluke 754 Documenting Process Calibrator-HART—the process industry’s most trusted multi-function calibrator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 22.3827%;\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eRange\/ Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e\u003cstrong\u003e1 Year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e\u003cstrong\u003e2 Years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e100.000 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 0.005 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.03% + 0.005 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e3.00000 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 0.00005 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.03% + 0.00005 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e30.0000 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 0.0005 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.03% + 0.0005 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e300.00 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.05% + 0.05 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.07% + 0.05 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e3.000 V (40 Hz to 500 Hz) \/ 0.001 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.5% + 0.002 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e1.0% + 0.004 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e30.00 V (40 Hz to 500 Hz) \/ 0.01 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.5% + 0.02 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e1.0% + 0.04 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e300.0 V (40 Hz to 500 Hz) \/ 0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.5% + 0.2 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e1.0% + 0.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 22.3827%;\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e30.000 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 5 uA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 7 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e110.00 mA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 20 uA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 30 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e10.000 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.05% + 50 mΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.07% + 70 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e100.00 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.05% + 50 mΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.07% + 70 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1.0000 kΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.05% + 500 mΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.07% + 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e10.000 kΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.1% + 10 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.15% + 15 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e1.00 to 110.00 Hz \/ 0.01 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.05 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e110.1 to 1100.0 Hz \/ 0.1 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1.101 to 11.000 kHz \/ 0.001 kHz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.005 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e11.01 to 50.00 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.05 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eSource Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e\u003cstrong\u003e1 Year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e\u003cstrong\u003e2 Years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e100.000 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 0.005 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 0.005 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1.00000 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 0.00005 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 0.0005 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e15.0000 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 0.0005 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 0.0005 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 22.3827%;\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e22.000 mA (source)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 0.003 mA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.02% + 0.003 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eCurrent sink (simulate)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 0.007 mA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.04% + 0.007 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e10.000 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 10 mΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 15 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e100.00 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.01% + 20 mΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.015% + 30 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1.0000 kΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 0.2 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.03% + 0.3 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e10.000 kΩ\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.02% + 3 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.03% + 5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 22.3827%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e0.1 to 10.99 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.01 to 10.99 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e11.00 to 109.99 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e110.0 to 1099.9 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1.100 to 21.999 kHz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.002 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e22.000 to 50.000 kHz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.005 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 22.3827%;\"\u003eData log functions\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eMeasure functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003eVoltage, current, resistance, frequency, temperature, pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eReading rate\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e1, 2, 5, 10, 20, 30, or 60 readings\/minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eMaximum record length\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e8000 readings (7980 for 30 or 60 readings\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.2022%;\"\u003eRamp functions\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 39.1697%;\"\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003eRate\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 39.1697%;\"\u003e4 steps\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003eTrip detect\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 39.1697%;\"\u003eContinuity or voltage (continuity detection not available when sourcing current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eLoop power function\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003eSelectable, 26 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e10%, 18 V minimum at 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eMaximum current\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e25 mA, short circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e50 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eStep functions\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eManual step\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003eSelectable step, change with arrow buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003eAutostep\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003eFully programmable for function, start delay, stepvalue, time per step, repeat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eDust\/water resistance\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003eMeets IP52, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e3000 m above mean sea level (9842 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003eCAN\/CSA C22.2 No 1010.1-92, ASNI\/ISA S82.01-1994, UL3111, and EN610-1:1993\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e1.2 kg (2.7 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003eInternal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e\u0026gt;8 hours typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eBattery replacement\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003eReplace without opening calibrator; no tools required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eSide port connections\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003ePressure module connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 75.8123%;\"\u003eUSB Connector to interface to your PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 75.8123%;\"\u003eDigital instrument (HART) connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 75.8123%;\"\u003eConnection for optional battery charger\/eliminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eData storage capacity\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003e1 week of calibration procedures results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003e90 day specifications\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"width: 75.8123%;\"\u003eThe standard specification interval for the 750 Seriesare 1 and 2 years.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 75.8123%;\"\u003eTypical 90 day measurement and source accuracy can be estimated by dividing the one year \"% of reading\" or \"% of output\" specifications by 2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 75.8123%;\"\u003eFloor specifications, expressed as \"% of full scale\" or \"counts\" or \"ohms\" remain constant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eTemperature, Resistance Temperature Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eDegrees or % of reading - Type (α)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eRange °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 53.6101%;\"\u003e\u003cstrong\u003eMeasure °C\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 44.5848%;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e\u003cstrong\u003e1 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e\u003cstrong\u003e2 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e100 Ω Pt (385)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 800\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.07°C\u003cbr\u003e0.02% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.14°C\u003cbr\u003e0.04% + 0.10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e200 Ω Pt (385)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 630\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.07°C\u003cbr\u003e0.02% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.14°C\u003cbr\u003e0.04% + 0.10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e500 Ω Pt (385)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 630\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.07°C\u003cbr\u003e0.02% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.14°C\u003cbr\u003e0.04% + 0.10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e1000 Ω Pt (385)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 630\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.07°C\u003cbr\u003e0.02% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.14°C\u003cbr\u003e0.04% + 0.10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e100 Ω Pt (3916)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 630\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.07°C\u003cbr\u003e0.02% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.14°C\u003cbr\u003e0.04% + 0.10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e100 Ω Pt (3926)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 100\u003cbr\u003e100 to 630\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.08°C\u003cbr\u003e0.02% + 0.06°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.16°C\u003cbr\u003e0.04% + 0.12°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e10 Ω Cu (427)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 260\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.2°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e120 Ω Ni (672)\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-80 to 260\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.1°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eSource current\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 48.7365%;\"\u003e\u003cstrong\u003eSource °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e\u003cstrong\u003eAllowable current\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e1 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e\u003cstrong\u003e2 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.05°C\u003cbr\u003e0.0125% + 0.04°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.10°C\u003cbr\u003e0.025% + 0.08°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e500 μA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.06°C\u003cbr\u003e0.017% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.12°C\u003cbr\u003e0.034% + 0.10°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e250 μA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.06°C\u003cbr\u003e0.017% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.12°C\u003cbr\u003e0.034% + 0.10°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e150 μA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.06 C\u003cbr\u003e0.017% + 0.05°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.12 C\u003cbr\u003e0.034% + 0.10°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.05°C\u003cbr\u003e0.0125% + 0.04°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.10°C\u003cbr\u003e0.025% + 0.08°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.05°C\u003cbr\u003e0.0125% + 0.04°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.10°C\u003cbr\u003e0.025% + 0.08°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e3 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.2°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.4°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0.04°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e0.08°C\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e0.1 mA to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"6\" style=\"width: 98.1949%;\"\u003e1. For two and three-wire RTD measurements, add 0.4°C to the specifications.\u003cbr\u003e2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 98.1949%;\"\u003e\u003cstrong\u003eTemperature, Thermocouples\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003eSource °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 26.5343%;\"\u003e\u003cstrong\u003eMeasure °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 27.0758%;\"\u003e\u003cstrong\u003eSource °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.3827%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e\u003cstrong\u003e1 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e\u003cstrong\u003e2 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e\u003cstrong\u003e1 year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e\u003cstrong\u003e2 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eE\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-250 to -200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to -100\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 600\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e600 to 1000\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eN\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-200 to -100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 900\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e900 to 1300\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eJ\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-210 to -100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 800\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e800 to 1200\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eK\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-200 to -100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.7\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 400\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e400 to 1200\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1200 to 1372\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.7\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eT\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-250 to -200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.7\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-200 to 0\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0 to 400\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e600 to 800\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e800 to 1000\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1000 to 1820\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eR\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-20 to 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e2.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0 to 100\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.2\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e100 to 1767\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eS\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-20 to 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e2.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0 to 200\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.1\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e200 to 1400\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1400 to 1767\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.7\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 22.3827%;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e0 to 800\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e800 to 1200\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.7\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1200 to 1800\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1800 to 2316\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e3.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e1.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eL\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-200 to -100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e-100 to 800\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e800 to 900\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 22.3827%;\"\u003eU\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-200 to 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e0 to 600\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 22.3827%;\"\u003eBP\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e0 to 1000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e1000 to 2000\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e1.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e2.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e2000 to 2500\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e2.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e3.0\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.8\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 22.3827%;\"\u003eXK\u003c\/td\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e\u003cstrong\u003e-200 to 300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.2\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.2022%;\"\u003e300 to 800\u003c\/td\u003e\n\u003ctd style=\"width: 14.4404%;\"\u003e0.4\u003c\/td\u003e\n\u003ctd style=\"width: 12.0939%;\"\u003e0.6\u003c\/td\u003e\n\u003ctd style=\"width: 12.4549%;\"\u003e0.3\u003c\/td\u003e\n\u003ctd style=\"width: 14.6209%;\"\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568579502259,"sku":"87434500","price":15970.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/30abc167-e10a-4eae-83b9-b108002bcb43_product_slideshow_main2x.webp?v=1781164203"},{"product_id":"fluke-isee™-mobile-thermal-camera-tc01a-android-usb-c-tc01b-apple-lightning","title":"Fluke iSee™ Mobile Thermal Camera – TC01A (Android USB-C) \/ TC01B (Apple Lightning)","description":"\u003cdiv id=\"overview_content\"\u003e\n\u003ch4 data-start=\"93\" data-end=\"145\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"98\" data-end=\"145\"\u003eProfessional Thermal Imaging in Your Pocket\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"147\" data-end=\"513\"\u003eTurn your smartphone into a powerful thermal imaging camera with the \u003cstrong data-start=\"216\" data-end=\"247\"\u003eFluke iSee™ TC01A and TC01B\u003c\/strong\u003e. Designed for electricians, HVAC technicians, plumbers, builders, maintenance professionals, automotive technicians, inspectors, and serious DIY users, the Fluke iSee delivers professional-grade thermal imaging in an ultra-compact device weighing just \u003cstrong data-start=\"500\" data-end=\"512\"\u003e22 grams\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"515\" data-end=\"841\"\u003eWith a \u003cstrong data-start=\"522\" data-end=\"555\"\u003e256 × 192 infrared resolution\u003c\/strong\u003e, \u003cstrong data-start=\"557\" data-end=\"578\"\u003e25Hz refresh rate\u003c\/strong\u003e, and a temperature range up to \u003cstrong data-start=\"610\" data-end=\"619\"\u003e550°C\u003c\/strong\u003e, the Fluke iSee makes it easy to locate electrical hot spots, overheating components, insulation defects, water leaks, HVAC issues, blocked pipes, underfloor heating faults, and mechanical problems quickly and accurately.\u003c\/p\u003e\n\u003cp data-start=\"843\" data-end=\"1051\"\u003eWhether you're performing preventative maintenance, troubleshooting equipment, or conducting building inspections, the Fluke iSee combines trusted Fluke reliability with the convenience of your mobile device.\u003c\/p\u003e\n\u003chr data-start=\"1053\" data-end=\"1056\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1058\" data-end=\"1073\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1075\" data-end=\"1827\"\u003e\n\u003cli data-section-id=\"1fomfvq\" data-start=\"1075\" data-end=\"1128\"\u003eHigh-resolution \u003cstrong data-start=\"1093\" data-end=\"1112\"\u003e256 × 192 pixel\u003c\/strong\u003e infrared sensor\u003c\/li\u003e\n\u003cli data-section-id=\"id1lr5\" data-start=\"1129\" data-end=\"1168\"\u003eMeasures temperatures up to \u003cstrong data-start=\"1159\" data-end=\"1168\"\u003e550°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1natedc\" data-start=\"1169\" data-end=\"1256\"\u003eThermal sensitivity of \u003cstrong data-start=\"1194\" data-end=\"1211\"\u003e50mK (0.05°C)\u003c\/strong\u003e for detecting subtle temperature differences\u003c\/li\u003e\n\u003cli data-section-id=\"b8cdpw\" data-start=\"1257\" data-end=\"1295\"\u003e\n\u003cstrong data-start=\"1259\" data-end=\"1274\"\u003e±2°C or ±2%\u003c\/strong\u003e measurement accuracy\u003c\/li\u003e\n\u003cli data-section-id=\"amrchg\" data-start=\"1296\" data-end=\"1350\"\u003eSmooth \u003cstrong data-start=\"1305\" data-end=\"1313\"\u003e25Hz\u003c\/strong\u003e frame rate for real-time inspections\u003c\/li\u003e\n\u003cli data-section-id=\"hrws5r\" data-start=\"1351\" data-end=\"1409\"\u003eLightweight aluminium construction weighing only \u003cstrong data-start=\"1402\" data-end=\"1409\"\u003e22g\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3hv53w\" data-start=\"1410\" data-end=\"1467\"\u003eProfessional Fluke iSee App with reporting and analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1w6qi3t\" data-start=\"1468\" data-end=\"1502\"\u003eMore than \u003cstrong data-start=\"1480\" data-end=\"1502\"\u003e10 colour palettes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u3jqt1\" data-start=\"1503\" data-end=\"1571\"\u003eAdjustable emissivity for accurate readings on different materials\u003c\/li\u003e\n\u003cli data-section-id=\"12pip7l\" data-start=\"1572\" data-end=\"1610\"\u003eLive high \u0026amp; low temperature tracking\u003c\/li\u003e\n\u003cli data-section-id=\"14uo7gk\" data-start=\"1611\" data-end=\"1631\"\u003eTemperature alarms\u003c\/li\u003e\n\u003cli data-section-id=\"4ni1rx\" data-start=\"1632\" data-end=\"1662\"\u003eTime-lapse thermal recording\u003c\/li\u003e\n\u003cli data-section-id=\"mtdscs\" data-start=\"1663\" data-end=\"1698\"\u003eAutomatic image and video capture\u003c\/li\u003e\n\u003cli data-section-id=\"17vqr34\" data-start=\"1699\" data-end=\"1749\"\u003eGenerate professional thermal inspection reports\u003c\/li\u003e\n\u003cli data-section-id=\"40vxn6\" data-start=\"1750\" data-end=\"1798\"\u003eIP54 (TC01A) \/ IP56 (TC01B) ingress protection\u003c\/li\u003e\n\u003cli data-section-id=\"9c6vef\" data-start=\"1799\" data-end=\"1827\"\u003eDrop tested to \u003cstrong data-start=\"1816\" data-end=\"1827\"\u003e1 metre\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1829\" data-end=\"1832\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"1834\" data-end=\"1855\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"1857\" data-end=\"1869\"\u003ePerfect for:\u003c\/p\u003e\n\u003cul data-start=\"1871\" data-end=\"2178\"\u003e\n\u003cli data-section-id=\"g688r7\" data-start=\"1871\" data-end=\"1907\"\u003eElectrical switchboards and panels\u003c\/li\u003e\n\u003cli data-section-id=\"1ikcqtw\" data-start=\"1908\" data-end=\"1934\"\u003ePreventative maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"1pvwt2r\" data-start=\"1935\" data-end=\"1957\"\u003eBuilding inspections\u003c\/li\u003e\n\u003cli data-section-id=\"1p39er5\" data-start=\"1958\" data-end=\"1980\"\u003eWater leak detection\u003c\/li\u003e\n\u003cli data-section-id=\"1vn7ez0\" data-start=\"1981\" data-end=\"1997\"\u003eHVAC servicing\u003c\/li\u003e\n\u003cli data-section-id=\"y8l88d\" data-start=\"1998\" data-end=\"2030\"\u003eUnderfloor heating inspections\u003c\/li\u003e\n\u003cli data-section-id=\"5i3m71\" data-start=\"2031\" data-end=\"2065\"\u003eMechanical equipment diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"1nc0rlw\" data-start=\"2066\" data-end=\"2092\"\u003eAutomotive fault finding\u003c\/li\u003e\n\u003cli data-section-id=\"tw3q40\" data-start=\"2093\" data-end=\"2118\"\u003eSolar panel inspections\u003c\/li\u003e\n\u003cli data-section-id=\"pzv7i2\" data-start=\"2119\" data-end=\"2141\"\u003ePlumbing diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"kqb733\" data-start=\"2142\" data-end=\"2178\"\u003eHome energy efficiency inspections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2180\" data-end=\"2183\"\u003e\n\u003ch2 data-section-id=\"rnswf4\" data-start=\"2185\" data-end=\"2204\"\u003eAvailable Models\u003c\/h2\u003e\n\u003ch3 data-section-id=\"17vu2ps\" data-start=\"2206\" data-end=\"2221\"\u003eFluke TC01A\u003c\/h3\u003e\n\u003cul data-start=\"2222\" data-end=\"2290\"\u003e\n\u003cli data-section-id=\"1oupmzv\" data-start=\"2222\" data-end=\"2271\"\u003eDesigned for \u003cstrong data-start=\"2237\" data-end=\"2271\"\u003eAndroid™ and HarmonyOS devices\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1d4387o\" data-start=\"2272\" data-end=\"2290\"\u003eUSB-C connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17vu2pv\" data-start=\"2292\" data-end=\"2307\"\u003eFluke TC01B\u003c\/h3\u003e\n\u003cul data-start=\"2308\" data-end=\"2457\"\u003e\n\u003cli data-section-id=\"1m54ide\" data-start=\"2308\" data-end=\"2365\"\u003eDesigned for \u003cstrong data-start=\"2323\" data-end=\"2365\"\u003eApple iPhone® with Lightning connector\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"617o89\" data-start=\"2366\" data-end=\"2457\"\u003eCompatible with Lightning-equipped iPhones (adapter required for iPhone 15 if applicable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2459\" data-end=\"2462\"\u003e\n\u003ch2 data-section-id=\"meetk4\" data-start=\"2464\" data-end=\"2494\"\u003eProfessional Fluke iSee App\u003c\/h2\u003e\n\u003cp data-start=\"2496\" data-end=\"2567\"\u003eThe free Fluke iSee App unlocks advanced inspection features including:\u003c\/p\u003e\n\u003cul data-start=\"2569\" data-end=\"2833\"\u003e\n\u003cli data-section-id=\"oco0jb\" data-start=\"2569\" data-end=\"2591\"\u003eLive thermal imaging\u003c\/li\u003e\n\u003cli data-section-id=\"1qgogg\" data-start=\"2592\" data-end=\"2634\"\u003eSpot, line and area temperature analysis\u003c\/li\u003e\n\u003cli data-section-id=\"12izp2y\" data-start=\"2635\" data-end=\"2670\"\u003eAutomatic hot\/cold spot detection\u003c\/li\u003e\n\u003cli data-section-id=\"1c4dlm0\" data-start=\"2671\" data-end=\"2689\"\u003eImage annotation\u003c\/li\u003e\n\u003cli data-section-id=\"sphu8v\" data-start=\"2690\" data-end=\"2715\"\u003eThermal video recording\u003c\/li\u003e\n\u003cli data-section-id=\"kbj6xi\" data-start=\"2716\" data-end=\"2740\"\u003eTime-lapse inspections\u003c\/li\u003e\n\u003cli data-section-id=\"l8x8d5\" data-start=\"2741\" data-end=\"2777\"\u003eProfessional PDF report generation\u003c\/li\u003e\n\u003cli data-section-id=\"k5gkie\" data-start=\"2778\" data-end=\"2796\"\u003eImage comparison\u003c\/li\u003e\n\u003cli data-section-id=\"1nzs4jn\" data-start=\"2797\" data-end=\"2833\"\u003eEasy sharing of inspection results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2835\" data-end=\"2838\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2840\" data-end=\"2867\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2869\" data-end=\"3281\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2869\" data-end=\"2902\"\u003e\n\u003ctr data-start=\"2869\" data-end=\"2902\"\u003e\n\u003cth data-start=\"2869\" data-end=\"2885\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2885\" data-end=\"2902\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eTC01A \/ TC01B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2937\" data-end=\"3281\"\u003e\n\u003ctr data-start=\"2937\" data-end=\"2979\"\u003e\n\u003ctd data-start=\"2937\" data-end=\"2959\" data-col-size=\"sm\"\u003eInfrared Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2959\" data-end=\"2979\"\u003e256 × 192 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2980\" data-end=\"3019\"\u003e\n\u003ctd data-start=\"2980\" data-end=\"3002\" data-col-size=\"sm\"\u003eThermal Sensitivity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3002\" data-end=\"3019\"\u003e50mK (0.05°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3020\" data-end=\"3055\"\u003e\n\u003ctd data-start=\"3020\" data-end=\"3040\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3040\" data-end=\"3055\"\u003eUp to 550°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3056\" data-end=\"3082\"\u003e\n\u003ctd data-start=\"3056\" data-end=\"3067\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"3067\" data-end=\"3082\" data-col-size=\"sm\"\u003e±2°C or ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3083\" data-end=\"3104\"\u003e\n\u003ctd data-start=\"3083\" data-end=\"3096\" data-col-size=\"sm\"\u003eFrame Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3096\" data-end=\"3104\"\u003e25Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3105\" data-end=\"3134\"\u003e\n\u003ctd data-start=\"3105\" data-end=\"3121\" data-col-size=\"sm\"\u003eField of View\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3121\" data-end=\"3134\"\u003e56° × 42°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3135\" data-end=\"3162\"\u003e\n\u003ctd data-start=\"3135\" data-end=\"3152\" data-col-size=\"sm\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3152\" data-end=\"3162\"\u003e8–14μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3163\" data-end=\"3180\"\u003e\n\u003ctd data-start=\"3163\" data-end=\"3171\" data-col-size=\"sm\"\u003eFocus\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3171\" data-end=\"3180\"\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3181\" data-end=\"3197\"\u003e\n\u003ctd data-start=\"3181\" data-end=\"3190\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3190\" data-end=\"3197\"\u003e22g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3198\" data-end=\"3230\"\u003e\n\u003ctd data-start=\"3198\" data-end=\"3219\" data-col-size=\"sm\"\u003eOperating Distance\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3219\" data-end=\"3230\"\u003e0.25–5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3231\" data-end=\"3281\"\u003e\n\u003ctd data-start=\"3231\" data-end=\"3251\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3251\" data-end=\"3281\"\u003eIP54 (TC01A), IP56 (TC01B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3283\" data-end=\"3286\"\u003e\n\u003ch2 data-section-id=\"1bbz3lg\" data-start=\"3288\" data-end=\"3317\"\u003eWhy Buy from Beyond Tools?\u003c\/h2\u003e\n\u003cp data-start=\"3319\" data-end=\"3394\"\u003eAs an Australian supplier of professional trade tools, Beyond Tools offers:\u003c\/p\u003e\n\u003cul data-start=\"3396\" data-end=\"3559\"\u003e\n\u003cli data-section-id=\"hulwpm\" data-start=\"3396\" data-end=\"3420\"\u003eGenuine Fluke products\u003c\/li\u003e\n\u003cli data-section-id=\"po62z5\" data-start=\"3421\" data-end=\"3444\"\u003eExpert product advice\u003c\/li\u003e\n\u003cli data-section-id=\"1u4fop8\" data-start=\"3445\" data-end=\"3475\"\u003eFast Australia-wide shipping\u003c\/li\u003e\n\u003cli data-section-id=\"18x7fxw\" data-start=\"3476\" data-end=\"3504\"\u003eTrusted service since 1986\u003c\/li\u003e\n\u003cli data-section-id=\"1vcozf3\" data-start=\"3505\" data-end=\"3559\"\u003eSupport for professionals, tradespeople and industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-carousel\"\u003e\n\u003cdiv id=\"slide-container\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"TC101A - Suit Android USB-C Smartphone Device","offer_id":45683569492147,"sku":"87433540","price":599.0,"currency_code":"AUD","in_stock":true},{"title":"TC101B - Suit IOS Lighting Smartphone Device (Adaptor Required for USB-C Device)","offer_id":45683569524915,"sku":"8044077","price":708.95,"currency_code":"AUD","in_stock":true},{"title":"TC101C - Suit IOS USB-C Smartphone Device","offer_id":45683569557683,"sku":"8044078","price":708.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/c9a53b44-981c-4275-8aad-b36300116d12_product_slideshow_main.jpg?v=1783957212"},{"product_id":"fluke-charging-base-ti-sbc3b","title":"Fluke Charging Base TI-SBC3B","description":"\u003cp\u003e\u003cspan\u003eCharging base for TiX560, TiX520, TiX500, Ti400, Ti300, Ti200, TiS75, TiS65, TiS60, TiS55, TiS50, TiS45, TiS40, TiS20, TiS10, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, TIR32, Ti29, TiR29, Ti27, and TiR27 infrared cameras.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568594051251,"sku":"8730710","price":498.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/55ead63b-1369-4f5d-b5bc-b108002d657b_product_slideshow_main2x.webp?v=1781163475"},{"product_id":"fluke-true-rms-ac-dc-clamp-meter-375fc","title":"Fluke True-RMS AC\/DC Clamp Meter 375FC","description":"\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"overview-label\" class=\"tab-pane active\" id=\"overview-tab\" tabindex=\"0\"\u003e\n\u003csection id=\"fluke-product-display-overview-section\"\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 375 FC True-RMS AC\/CD Clamp Meter measures very low voltage and very high resistance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect\u003c\/p\u003e\n\u003cp\u003eThe 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWireless connectivity improves productivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"ed45dced34aab859e62d8b369d59ca591\"\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli data-list-item-id=\"e3d81f9f73132ec62c99825d2045c7f9d\"\u003eComes with batteries, soft carrying case, and three-year warranty\u003c\/li\u003e\n\u003cli data-list-item-id=\"e1106c1ded6014150116de3bed998af49\"\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli data-list-item-id=\"efd18f6ae3c1b83dea9772df845b6d0d6\"\u003eMeasures capacitance to 1000 µF\u003c\/li\u003e\n\u003cli data-list-item-id=\"e91a6947f62891e8950f342453214ff40\"\u003eIncludes True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli data-list-item-id=\"ec97986eb99b09e4086eccfc203a1ab9d\"\u003eMeasures frequency to 500 Hz and resistance to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli data-list-item-id=\"ecb03dc7190de10b573c6fc45672ea89a\"\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli data-list-item-id=\"ea9baab4b13382d11a099f797600137cf\"\u003eOffers 500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli data-list-item-id=\"e09b902888228d3cac0e5badf79de620b\"\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-right\"\u003e\n\u003cdiv id=\"fluke-product-display-box-contents\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"e75ddfdda81f11a38cebc84dc9306caad\"\u003e375 FC AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli data-list-item-id=\"eba8c361634b88a3a6c03d7ae5eff37c3\"\u003e(1 pair) TL75 test leads\u003c\/li\u003e\n\u003cli data-list-item-id=\"ed8450aeeda7cabfea4264df51906d4f1\"\u003eTwo AA Alkaline batteries (Installed)\u003c\/li\u003e\n\u003cli data-list-item-id=\"e11bb1e8223c3b9c99a0565dcc286edb5\"\u003eSoft carrying case\u003c\/li\u003e\n\u003cli data-list-item-id=\"e58678857857a30a8405dca6026721777\"\u003eQuick Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eAC Current via Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 29.8653%;\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eAC Current via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 29.8653%;\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003ePosition Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/f3cfc638-13b3-4358-9cd8-b108002b2e9f_original__size.jpg\" alt=\"Flexible current probe\" width=\"100\" height=\"67\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e\u003cstrong\u003ei2500-10 Flex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e\u003cstrong\u003ei2500-18 Flex\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eError\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e±0.5 %\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eError\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e±1.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eError\u003c\/td\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e±2.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 99.278%;\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003emV dc\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eFrequency via Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 29.8653%;\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eFrequency via Flexible Current Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 29.8653%;\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 29.8653%;\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 29.8653%;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.0625%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.3502%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eElectromagnetic Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 29.8653%;\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 29.8653%;\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 69.4127%;\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.8653%;\"\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 69.4127%;\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfooter id=\"fluke-product-display-footer\"\u003e\n\u003cdiv class=\"disclaimer\"\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003eFluke Connect is not available in all countries.\u003c\/h6\u003e\n\u003ch6\u003e*Not all models are available in all countries. Check with your local Fluke representative.\u003c\/h6\u003e\n\u003ch6\u003e©2026Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4s and up running iOS 8 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.\u003c\/h6\u003e\n\u003c\/div\u003e\n\u003c\/footer\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568595886259,"sku":"87434501","price":1060.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/6cdecd59-cb0b-43ed-aafa-b108002e1b3d_product_slideshow_main2x.webp?v=1781164095"},{"product_id":"fluke-milliamp-process-clamp-loop-meter-772","title":"Fluke Milliamp Process Clamp Loop Meter 772","description":"\u003cp\u003eThe Fluke 772 loop meter adds to the basic capabilities of the Fluke 771 to save more time and expand its applications. With the 771, you'll also be able to: source and simulate 4-20 mA signals for testing control system I\/O; measure 4-20 mA signals with in-circuit measurement; power a transmitter with the 24 V loop power supply; and automatically ramp and step change the 4-20 mA output for remote testing.\u003c\/p\u003e\n\u003cp\u003eYou'll be able to test 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down, which can save you time, and help you avoid possibly missing something going on in the process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimulates 4-20 mA signals for testing control system I\/O\u003c\/li\u003e\n\u003cli\u003eSources 4 to 20 mA signals for testing control system I\/O or I\/Ps\u003c\/li\u003e\n\u003cli\u003eMeasures 4 to 20 mA signals with in-circuit measurement\u003c\/li\u003e\n\u003cli\u003eIncludes simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters\u003c\/li\u003e\n\u003cli\u003eFeatures a detachable clamp with extension cable for measurements in tight locations\u003c\/li\u003e\n\u003cli\u003eCaptures and displays changing measurements with Hold function\u003c\/li\u003e\n\u003cli\u003eOffers mA output linear ramp or 25% step output\u003c\/li\u003e\n\u003cli\u003eExtends battery life with auto-off and backlight timeout\u003c\/li\u003e\n\u003cli\u003eDual backlit display with both mA measurement and percent of 4 to 20 mA span\u003c\/li\u003e\n\u003cli\u003eMeasurement Spotlight to illuminate hard to see wires in dark enclosures\u003c\/li\u003e\n\u003cli\u003eMeasures 10 to 50 mA signals in older control systems using the 99.9 mA range\u003c\/li\u003e\n\u003cli\u003eAutomatically changes the 4 to 20 mA output for remote testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.177” or 4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 to 50ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-25 to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 90% @ \u0026lt;30ºC, \u0026lt; 75% @ 30 to 55ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e410 g, (14.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop test (except the jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeets EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"2\"\u003eFor current measurement w\/ JAW, add 1mA to specification for EMC field strengths of 1V\/m up to 3V\/m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% ºC\u003cbr\u003e(\u0026lt; 18ºC or \u0026gt; 28ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years for electronics\u003cbr\u003eOne year for cable and clamp assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"35%\"\u003emA measurement\u003cbr\u003e(measured by clamp)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \/ range\u003c\/td\u003e\n\u003ctd\u003e21.0mA to 100.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA measurement (measured in series with test jacks)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA source (maximum mA drive: 24 mA into 1,000 ohms)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA simulate (maximum voltage 50 V dc)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568602243251,"sku":"1042098","price":2299.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a6ba9d3c-026c-430a-bca8-b108002bcccd_product_slideshow_main2x.webp?v=1781164505"},{"product_id":"fluke-milliamp-process-clamp-meter-773","title":"Fluke Milliamp Process Clamp Meter 773","description":"\u003ch3\u003eSave time and money by measuring output signals without shutting down the system\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4–20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.\u003c\/p\u003e\n\u003cp\u003eThe 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.\u003c\/p\u003e\n\u003cp\u003eThe 773 also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWork smarter with the 778 mA Clamp Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn integrated measurement spotlight allows you to illuminate hard to see wires in dark enclosures while a dual backlit display can show mA measurement and percent of 4 to 20 mA span simultaneously. Use the Hold function to capture measurements on-screen for verification and recording purposes. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced loop troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing transmitter. You can also apply a mA input signal to a device and measure its 4-20 mA output on devices such as valves or mA isolators. Offers mA or voltage output linear ramp or 25% step output.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.177\" or 4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 to 50ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-25 to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 90% @ \u0026lt;30ºC, \u0026lt; 75% @ 30 to 55ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e410 g, (14.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop test (except the jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeets EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"2\"\u003eFor current measurement w\/ JAW, add 1mA to specification for EMC field strengths of 1V\/m up to 3V\/m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% ºC\u003cbr\u003e(\u0026lt; 18ºC or \u0026gt; 28ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years for electronics\u003cbr\u003eOne year for cable and clamp assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"25%\"\u003emA measurement\u003cbr\u003e(measured by clamp)\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e0 to 20.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \/ range\u003c\/td\u003e\n\u003ctd\u003e21.0mA to 100.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA measurement (measured in series with test jacks)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA source (maximum mA drive: 24 mA into 1,000 ohms)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA simulate (maximum voltage 50 V dc)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage source (2 mA maximum drive current)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage measure\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 30.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45568602603699,"sku":"1041173","price":3165.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/2f068289-4b8a-4621-936a-b108002e449f_product_slideshow_main2x.webp?v=1781164749"},{"product_id":"fluke-diagnostic-video-borescope-ds703fc","title":"Fluke Diagnostic Video Borescope DS703FC","description":"\u003cp\u003eThe Fluke DS703 FC Video Borescope has been updated with improved battery charging and management and can now last up to 4 hours on a single charge.\u003c\/p\u003e\n\u003cp\u003e7” capacitive touch screen for accurate diagnostics in difficult to reach spaces. 720p video recording inspection camera. Adjustable LED lighting and digital zoom for quality images. Up is Up® technology rotates the display screen to allow for appropriate image display, regardless of the orientation of the probe. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSave time with the Fluke Connect® system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWirelessly sync images directly from your diagnostic scope to the Fluke Connect® system. Having access to maintenance records simultaneously at the inspection site and from the office or an off-site location enables faster decision making and real-time collaboration between team members.\u003c\/p\u003e\n\u003cp\u003eExpand the flexibility of your video borescope with optional probes offering cameras that range in diameter from 3.8 MM to 8.5 MM, probes as long as 20 meters, and a new camera probe with a 180° degree articulating head. Equip yourself with the right probe for your environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 78.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6096%; height: 19.5938px;\"\u003e\u003cstrong\u003eLCD Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.0294%; height: 19.5938px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6096%; height: 19.5938px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"width: 72.0294%; height: 19.5938px;\"\u003e7 inch Capacitive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6096%; height: 19.5938px;\"\u003eRefresh rate\u003c\/td\u003e\n\u003ctd style=\"width: 72.0294%; height: 19.5938px;\"\u003e30 hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6096%; height: 19.5938px;\"\u003eLED backlight\u003c\/td\u003e\n\u003ctd style=\"width: 72.0294%; height: 19.5938px;\"\u003eAdjust display brightness for optimal viewing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 27.8056%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.8334%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8056%;\"\u003eWireless interface\u003c\/td\u003e\n\u003ctd style=\"width: 71.8334%;\"\u003eWiFi 802.11b\/g\/n, Range: 33 feet (10.06 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8056%;\"\u003eData transfer\u003c\/td\u003e\n\u003ctd style=\"width: 71.8334%;\"\u003eUSB and micro HDMI cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8056%;\"\u003eFlukeConnect™\u003c\/td\u003e\n\u003ctd style=\"width: 71.8334%;\"\u003eSave and share images via FlukeConnect™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.8056%;\"\u003eInstant upload to the cloud\u003c\/td\u003e\n\u003ctd style=\"width: 71.8334%;\"\u003eYes, with FlukeConnect™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 235.125px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eColor palettes\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003eVisible light, grayscale or inverted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eInternal memory\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e6 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 39.1875px;\"\u003ePhysical buttons\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 39.1875px;\"\u003eIntuitive, easy to navigate button technology, 4 functional keys, 4 navigational, one capture or select button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eCarrying case\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003eProtective EVA case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eStrap\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003eHand Strap and Neck Strap included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003ePower adapter\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003eAC adapter\/battery charger input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e6400mAh 3.7 volt rechargeable internal li-ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e3 hours at 50 % LED brightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e6.98 x 8.85 inches (17.73 x 22.48 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.6115%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 72.0275%; height: 19.5938px;\"\u003e1.95 lbs (0.88 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003e\u003cstrong\u003eGeneral Specifications and Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eTablet\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003eIP54, dust protected and protected against water projected from a nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eDrop test\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e2 meter (6.56 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e0 °C to 45 °C (32 °F to 113 °F), 50 °C (122 °F) for less than 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e-40 °C to 60 °C (-40 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e90 % at 35 °C (95 °F), 75 % at 40 °C (104 °F), 45 % at 50 °C (122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.6908%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 71.9482%;\"\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003e\u003cstrong\u003eVideo Borescope Probe Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e\u003cstrong\u003e8.5mm Dual View (1.2M) (Included with DS703 FC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eOuter Diameter of Tip\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e8.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e1.2 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e1280 x 720 (720p) (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eDepth of Field (min)\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e35.5mm (Front)\u003cbr\u003e35.5mm (Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eDepth of Field (max)\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e111.7mm (Front)\u003cbr\u003e111.7mm (Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eField of View\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e75 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eUp-is-Up™ technology\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eLength of Distal Tip\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e50mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eOuter Diameter of Conduit\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003e6.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eConduit Pliability\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eFlexible but compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eWaterproof\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eWaterproof to 2 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eLED Type\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eStandard white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eStill image format\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eJPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eVideo recording format\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eMPEG compression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eDigital zoom\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eAdjustable from 1x to\u003cbr\u003e8x zoom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eCamera Direction\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eFront and Side View\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7824%;\"\u003eStreaming video\u003c\/td\u003e\n\u003ctd style=\"width: 71.8566%;\"\u003eVia HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570170585267,"sku":"1041450","price":4450.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/1efb6a28-9e79-47cd-940a-b108002e6a80_product_slideshow_main2x.webp?v=1781243060"},{"product_id":"fluke-earth-ground-clamp-1630-2-fc","title":"Fluke Earth Ground Clamp 1630-2 FC","description":"\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"overview-label\" class=\"tab-pane active\" id=\"overview-tab\" tabindex=\"0\"\u003e\n\u003csection id=\"fluke-product-display-overview-section\"\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEarth ground ac leakage current measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/li\u003e\n\u003cli\u003eRugged heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLogging measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals\u003c\/li\u003e\n\u003cli\u003eSaves up to 32,760 measurements in memory at the set logging interval.\u003c\/li\u003e\n\u003cli\u003eSaves time by recording and storing measured values.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm threshold\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBand-pass filter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect® Wireless System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1630-2 FC supports the Fluke Connect Wireless System connects the clamp with an app on your smartphone or tablet (may not be available in all regions).\u003c\/li\u003e\n\u003cli\u003eYou can save these measurements, and images to Fluke Connect Cloud storage and share with your team.\u003c\/li\u003e\n\u003cli\u003eMaximize uptime and make confident maintenance decisions with data you can trust and trace.\u003c\/li\u003e\n\u003cli\u003eAccess baseline, historical and current measurements by asset.\u003c\/li\u003e\n\u003cli\u003eShare your measurement data using ShareLive™ video calls and emails.\u003c\/li\u003e\n\u003cli\u003eThe 1630-2 FC is part of a growing system of connected test tools and equipment maintenance software. Visit the website to learn more about the Fluke Connect system. Find out more at\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/connect.fluke.com\/en\/stores\/home\" class=\"ext\" data-extlink=\"\" rel=\"noopener noreferrer\" title=\"\" target=\"_blank\"\u003eflukeconnect.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-right\"\u003e\n\u003cdiv id=\"fluke-product-display-box-contents\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1630-2 FC Earth Ground Clamp\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eLoop resistance standard\u003c\/li\u003e\n\u003cli\u003e4 AA batteries\u003c\/li\u003e\n\u003cli\u003eSafety information guide\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 33.213%;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eDigital reading\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eRefresh rate\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e-20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 33.213%;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eNon condensing (\u0026lt;10 °C) (\u0026lt; 50 °F)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e(Non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e2000 m (6561 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e12 000 m (39,370 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eReference temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e23 °C ±5 °C (73 °F ±9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e0.15% x (specified accuracy)\/ °C (\u0026lt;18 °C or \u0026gt;28 °C [\u0026lt;64.4 °F or \u0026gt;82.4 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eOverload indication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eData logging capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eMinimum of 32,760 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eData logging interval\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1 second to 59 minutes and 59 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eDisplay reading specification with standard loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eInput (Ω)\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eMinimum\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003eMaximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.474\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e0.417\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e0.531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.5\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e0.443\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e0.558\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e9.55\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e10.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e96\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 61010-1: Pollution Degree 2 IEC\/EN 61557-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 61010-2-032: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eCurrent clamp for leakage current measurements\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eResistance to earth\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eEffectiveness of the Protective measures\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eIEC\/EN 61557-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 33.213%;\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 22.1403%;\"\u003eInternational\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003eIEC\/EN 61326-1: Portable Electromagnetic Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003eCISPR 11: Group 1, Class B, IEC\/EN 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eWireless Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eOutput power\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e\u0026lt;10 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eFCC ID:T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eConductor size\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e40 mm (1.57 in) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e880g (31 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eEarth Ground Loop Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.025 Ω to 0.249 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1.5% + 0.02 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.250 Ω to 0.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1.5% + 0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e1.000 Ω to 9.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1.5% + 0.10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e10.00 Ω to 49.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1.5% + 0.30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e50.00 Ω to 99.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e1.5% + 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e3.0% + 1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e200.0 Ω to 399.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e5.0% + 5.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e400 Ω to 599 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e10.0% + 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e600 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.065%;\"\u003e20.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e  Loop resistance with no inductance, conductor centered and perpendicular to jaw\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eEarth ground leakage current mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003eAutorange 50\/60 Hz, True rms, crest factor CF ≤3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.200 mA to 3.999 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e1 μA\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e2.0% + 0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e4.00 mA to 39.99 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e10 μA\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e2.0% + 0.03 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e40.0 mA to 399.9 mA\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e100 μA\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e2.0% + 0.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e0.400 A to 3.999 A\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e2.0% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.213%;\"\u003e4.00 A to 39.99 A\u003c\/td\u003e\n\u003ctd style=\"width: 22.1403%;\"\u003e10 mA\u003c\/td\u003e\n\u003ctd style=\"width: 43.9247%;\"\u003e2.0% + 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\n\u003cp\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eApplies to signal frequency\u003c\/small\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 1 kHz with filter set to OFF\u003c\/small\u003e\u003c\/li\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 70 Hz with filter se to ON\u003c\/small\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfooter id=\"fluke-product-display-footer\"\u003e\n\u003cdiv class=\"disclaimer\"\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch6\u003eFluke Connect is not available in all countries.\u003c\/h6\u003e\n\u003ch6\u003e*Not all models are available in all countries. Check with your local Fluke representative.\u003c\/h6\u003e\n\u003ch6\u003e©2026Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4s and up running iOS 8 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.\u003c\/h6\u003e\n\u003c\/div\u003e\n\u003c\/footer\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570175598771,"sku":"1041848","price":4098.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/17e87c66-77f1-4fa1-a3ae-b108002b04ac_product_slideshow_main2x.webp?v=1781243538"},{"product_id":"fluke-440ma-1000v-fuse-f440m1000","title":"Fluke 440mA 1000V Fuse F440M1000","description":"\u003cul\u003e\n\u003cli\u003e440 milliamp, 1000 volt fuse for Fluke digital multimeters\u003c\/li\u003e\n\u003cli\u003eHigh-energy and fast-release fuse designed measuring current\u003c\/li\u003e\n\u003cli\u003eSand-filled to quickly cut off available oxygen in case of short\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen an electrical short occurs while making a current measurement, the user relies upon the high-energy fuse in the test tool for protection. This 440 mA, 1000 V fuse is designed to keep the energy generated within the fuse enclosure, protecting the user from electric shock and burns. This fuse limits the length of time energy is applied and the amount of oxygen available for combustion.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 440 mA 1000 V high-energy fuse is sand-filled which helps absorb the shock energy created by the current overload. It also controls the potential high temperatures generated (up to 10,000 °F). The energy created from an electrical short will melt the sand, turning it to glass. This helps smother a potential fireball by quickly cutting off the available oxygen, further protecting the user.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570179891379,"sku":"1041461","price":30.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a47d604b-f3af-43e6-bd34-b108002e5597_product_slideshow_main2x.webp?v=1781244432"},{"product_id":"fluke-geo-earth-ground-tester-1625-2","title":"Fluke GEO Earth Ground Tester 1625-2","description":"\u003cp\u003e\u003cstrong\u003eGet fast, accurate earth ground testing using all four test methods\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKeep your options open\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf a bonded earth ground system does not exist for the building or structure under test, and there is only one path to ground, you can use the 1625-2 to perform the fall-of-potential test method with stakes.\u003c\/p\u003e\n\u003cp\u003eThe 1625-2 Earth Ground Tester offers other advanced features including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Frequency Control to identify existing interference and choose a measurement frequency to minimize its effect, thus providing a more accurate earth ground value.\u003c\/li\u003e\n\u003cli\u003eR* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1625-2 is also very easy to use. World class accessories speed set up and test time. And the tester tells you which stakes or clamps to connect for each test. The large rotary switch and buttons are easy to operate even with a gloved hand. And you can store up to 1500 records and access them easily via the USB port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see\u003c\/li\u003e\n\u003cli\u003eIncludes USB port for data storage and transfer\u003c\/li\u003e\n\u003cli\u003eFeatures IP56 rating for outdoor use\u003c\/li\u003e\n\u003cli\u003eOffers adjustable limits for quicker testing\u003c\/li\u003e\n\u003cli\u003eComes with a rugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 25.2708%;\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 25.2708%;\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eMeasurement of Interference Frequency (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eEarthing Resistance (RE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eElectrical Measurement Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e\u003cstrong\u003eReference Conditions or Specified Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003e\u003cstrong\u003eDesignation Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003e\u003cstrong\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003e\u003cstrong\u003eType of Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003eReference conditions\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003ePosition\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE1\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSupply voltage\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE2\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE3\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE4\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE5\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSystem frequency\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE7\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSystem voltage\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd style=\"width: 15.8845%;\"\u003eE8\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 38.4477%;\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 27.4368%;\"\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd style=\"width: 7.22022%;\"\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eE\u003csub\u003en\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 25.2708%;\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 25.2708%;\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e Clamp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 25.2708%;\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e\u003cstrong\u003e0.5 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 50.5415%;\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e\u003cstrong\u003e0.1 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 50.5415%;\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd style=\"width: 22.5632%;\"\u003e\u003cstrong\u003e3 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 50.5415%;\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\" style=\"width: 98.3755%;\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eResistance Measurement (R~)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 38.4477%;\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eResistance Measurement (R DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 98.3755%;\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\" style=\"width: 98.3755%;\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 98.3755%;\"\u003e\u003cstrong\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.2708%;\"\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 73.1047%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 25.2708%;\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\" style=\"width: 73.1047%;\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\" style=\"width: 98.3755%;\"\u003eMeasuring principle: Stakeless measurement of resistance in closed loops using two current transformers.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570183987379,"sku":"834190","price":8384.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/cadc5164-1e32-4ba0-b5b7-b29c01306c19_product_slideshow_main2x.webp?v=1781244775"},{"product_id":"fluke-geo-earth-ground-tester-kit-1625-2kit","title":"Fluke GEO Earth Ground Tester Kit 1625-2KIT","description":"\u003cp\u003e\u003cstrong\u003eThe Most Complete Stakeless Earth Ground Tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless earth ground measurement testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil\u003c\/li\u003e\n\u003cli\u003eThe Fluke 1625-2 earth ground tester can measure earth ground loop resistances using only clamps\u003c\/li\u003e\n\u003cli\u003eWith this test method, two clamps are placed around the earth ground rod and each are connected to the tester\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1625-2 improves your earth ground testing process with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value\u003c\/li\u003e\n\u003cli\u003eR* measurement - calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see\u003c\/li\u003e\n\u003cli\u003eAdjustable limits - for quicker testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1625-2 gives you versatility in earth ground testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole fall-of-potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole soil resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1625-2 offers you simpler, faster earth ground tests than ever before\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1625-2 offers internal memory storage up to 1500 records\u003c\/li\u003e\n\u003cli\u003eAccessible via USB port for rapid data transfer and viewing of results\u003c\/li\u003e\n\u003cli\u003eThis earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional tool features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy duty stakes can be hammered into dry, hard soil.\u003c\/li\u003e\n\u003cli\u003eAnd new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50%\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eMeasurement of Interference Frequency (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eEarthing Resistance (RE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eElectrical Measurement Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic Error or Influence Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Conditions or Specified Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDesignation Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eEn = variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e Clamp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.5 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eResistance Measurement (R~)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eResistance Measurement (R DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasuring principle: Stakeless measurement of resistance in closed loops using two current transformers.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570185494707,"sku":"834192","price":10587.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a00898a0-ee66-483c-83c2-b108002b040b_product_slideshow_main2x.webp?v=1781245183"},{"product_id":"fluke-geo-earth-ground-resistance-meter-1623-2","title":"Fluke GEO Earth Ground Resistance Meter 1623-2","description":"\u003cp\u003e\u003cstrong\u003eFluke 1623-2 Earth Ground Tester performs all four ground tests quickly and accurately.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. You can use it to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKeep your options open\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKeep in mind, the stakeless test method works only if a bonded earth ground system exists for the building or structure under test. If there is only one path to ground, typical with many residential applications, you will need to use the fall-of-potential test method that requires stakes.\u003c\/p\u003e\n\u003cp\u003eThe 1625-2 is also very easy to use. World class accessories speed set up and test time. And the tester tells you which stakes or clamps to connect for each test. The large rotary switch and buttons are easy to operate even with a gloved hand. And you can store up to 1,500 records and access them easily via the USB port.\u003c\/p\u003e\n\u003cp\u003eNeed even more accuracy? Check out the 1625-2 that offers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Frequency Control that identifies existing interference and chooses a measurement frequency to minimize its effect, thus providing a more accurate earth ground value.\u003c\/li\u003e\n\u003cli\u003eR* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes USB port for data storage and transfer\u003c\/li\u003e\n\u003cli\u003eWorks with world class that speed set up and test time\u003c\/li\u003e\n\u003cli\u003eComes with a rugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"width: 35%;\" style=\"width: 24.9097%;\"\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eUser interface\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eClimatic class\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eProtective type\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eQuality system\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eExternal voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eV ext rejection\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring time\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMax. overload\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 99.639%;\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eR\u003csub\u003eA\u003c\/sub\u003e 4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 99.639%;\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e with Clamp )\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 99.639%;\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e with Clamp )\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 99.639%;\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eStakeless Ground Loop Measurement (2 Clamps)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eSwitch position\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eOperating error\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.639%;\"\u003e\u003cstrong\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.9097%;\"\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 24.9097%;\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd style=\"width: 74.7292%;\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 74.7292%;\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 99.639%;\"\u003e\n\u003cp\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570189459635,"sku":"834191","price":4194.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/64073a13-63c5-44ac-a1b6-b108002de877_product_slideshow_main2x.webp?v=1781245581"},{"product_id":"fluke-handheld-infrared-laser-thermometer-62-max","title":"Fluke Handheld Infrared Laser Thermometer 62 MAX+","description":"\u003cp\u003eThe Fluke 62 MAX+ Handheld Infrared Laser Thermometer delivers the accuracy you need in an extremely rugged package. Just point, shoot, and read the temperature of many types of equipment. Get accurate readings form transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IR thermometer’s small size and versatile features make it extremely easy to use. Plus, the lightweight form factor clips comfortably to your tool belt or belt loop, or easily fits in your toolbox. The 62 MAX+ offers a wide variety of features to take measurements quickly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"ea4a54b18a37505622c3e5d9220c2939a\"\u003eHigh and low alarms for rapid detection of measurements outside the limits\u003c\/li\u003e\n\u003cli data-list-item-id=\"ec9e5e69415c6714dfbc23b78e1114b08\"\u003eDisplays Min\/Max\/Avg\/Dif\u003c\/li\u003e\n\u003cli data-list-item-id=\"ea092e87ce4311268c22dc4bd56091e50\"\u003eThe minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003cli data-list-item-id=\"e55c1cb1c45c664cd3961b87efbca4f8f\"\u003eEasy to read, even in dark areas with large, backlit display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWorks every place you need to go\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 62 MAX+ is rugged enough to take a three-meter drop – good news if you work from a ladder. Dual lasers help you target your measurement; the 12:1 distance to spot ratio helps get the reading you want. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX+ to provide extremely accurate temperature measurements, rain or shine, even in dirty and dusty industrial sites.\u003c\/p\u003e\n\u003cp\u003ePowered by a single, standard AA battery.\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt;±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable electromagnetic equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution degree 2\u003cbr\u003eIEC 60825-1: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570231763123,"sku":"1041288","price":366.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/44da1b0d-d6a9-473c-95e7-b108005a2ed6_product_slideshow_main2x.webp?v=1781248761"},{"product_id":"fluke-hydraulic-test-pressure-kit-700htpk2","title":"Fluke Hydraulic Test Pressure Kit 700HTPK2","description":"\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eRugged, high-quality premium hydraulic pressure pump kit for fast and accurate test results generates pressure up to 10,000 psi, 690 bar. Includes the 700HTP-2 hydraulic hand pump, premium test hoses and adapters, and protective hard case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCombine with any Fluke 700G Series Gauge, 1,000 psi (69 bar) range or greater, to make a complete pressure testing kit\u003c\/li\u003e\n\u003cli\u003eGenerate pressure up to 10,000 psi, 690 bar with the included 700HTP-2 test pump\u003c\/li\u003e\n\u003cli\u003eConnect the 700G Series Gauge, directly to the HTP-2 hand pump with premium no tools required adapter\u003c\/li\u003e\n\u003cli\u003eHard case protects pump and gauge and allows gauge to remain connected to the pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570244903091,"sku":"1041573","price":3759.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/d6903233-8069-40ec-ac0b-b108002e3936_product_slideshow_main2x.webp?v=1781249004"},{"product_id":"fluke-insulation-multimeter-1577","title":"Fluke Insulation Multimeter 1577","description":"\u003cp\u003eThe Fluke 1577 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.\u003c\/p\u003e\n\u003cp\u003eWhether you work on motors, generators, cables, or switch gear, the Fluke 1577 Insulation Multimeter is ideally suited to help you with your tasks and at a cost that is far less than buying the two products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC millivolts\u003c\/li\u003e\n\u003cli\u003eResistance (0.1 Ω to 50 MΩ)\u003c\/li\u003e\n\u003cli\u003eContinuity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote probe, test leads, alligator clips\u003c\/li\u003e\n\u003cli\u003eRugged, utility hard case\u003c\/li\u003e\n\u003cli\u003eAuto power off to save battery power\u003c\/li\u003e\n\u003cli\u003eTrue RMS\u003c\/li\u003e\n\u003cli\u003eLarge display with backlight\u003c\/li\u003e\n\u003cli\u003eLive circuit detection prevents insulation test if voltage \u0026gt; 30 V is detected for added user protection\u003c\/li\u003e\n\u003cli\u003eCAT III 1000V, CAT IV 600V measurement category\u003c\/li\u003e\n\u003cli\u003eAccepts optional Fluke TPAK\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003emagnetic hanging system to free your hands for other work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 30.4145%;\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(0.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 30.4145%;\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 30.4145%;\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(1.0%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 30.4145%;\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(2.0%+2)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 30.4145%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMaximum resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(1.2%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003emaximum resolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eInsulation Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eMinimum test current @ 1kΩ\/V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 30.4145%;\"\u003eMaximum resistance per test voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e100 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e600 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 30.4145%;\"\u003eMaximum resolution per test voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e100 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 30.4145%;\"\u003eAccuracy per test voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e100 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e–20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e0% - 95% (10°C – 30°C)\u003cbr\u003e0% - 75% (30°C – 40°C)\u003cbr\u003e0% - 40% (40°C – 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003eIEC 61010-2-033: CAT IV 600V \/ CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.278%;\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e203 x 100 x 50 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e624 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 30.4145%;\"\u003eBattery life alkaline\u003c\/td\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003e\u003cstrong\u003eMeter use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003e1000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.9718%;\"\u003eInsulation test use\u003c\/td\u003e\n\u003ctd style=\"width: 39.8917%;\"\u003eMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4145%;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 68.8635%;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45570253586611,"sku":"87434502","price":1910.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/f5da69c6-7890-4ce7-820f-b108002de062_product_slideshow_main2x.webp?v=1781249479"},{"product_id":"fluke-726-precision-multifunction-calibrator-flu726","title":"Fluke 726 Precision Multifunction Calibrator FLU726","description":"\u003cp\u003e\u003cstrong\u003eProcess calibration designed specifically for process industries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and\/or sources pressure using when paired with any of the 50\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-750p\"\u003eFluke 750P series Pressure Modules\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eto test and calibrate pressure transmitters and other devices. The 726 can also:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSource mA with simultaneous pressure measurement to conduct valve and I\/P test\u003c\/li\u003e\n\u003cli\u003eConduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for ease of use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.\u003c\/p\u003e\n\u003cp\u003eYou can also use the 726 to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCapture the set, reset, and deadband of a pressure switch with the integrated switch test\u003c\/li\u003e\n\u003cli\u003eCalculate the transmitter error % to interpret calibration results without the use of a calculator\u003c\/li\u003e\n\u003cli\u003ePerform fast linearity tests with the auto-step and auto-ramp features\u003c\/li\u003e\n\u003cli\u003ePower a transmitter during test using 24 V loop supply and simultaneous mA measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you want documenting and HART communication built into your calibrator, consider the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/multifunction-calibrators\/fluke-754\"\u003eFluke 754 Documenting Process Calibrator with HART\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"25%\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30.000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (upper display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (lower display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24.000 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%+ 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.0 to 4000.0 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.00 to 15.00 kHz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e1 V peak-to-peak-minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSource Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100.00 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24.000 mA (Source)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24.000 mA (Simulate)\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResistance\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cstrong\u003eRange, accuracy (percent of reading + floor) and excitation current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 10.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 to 15.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003e5 V p-p squarewave, -0.1 V offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRTDs and Thermocouples\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"23\"\u003eMeasure and source accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCu10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNI-120\u003c\/td\u003e\n\u003ctd\u003e0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (385)\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (392)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (391-JIS)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-200 (385)\u003c\/td\u003e\n\u003ctd\u003e0.95°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-500 (385)\u003c\/td\u003e\n\u003ctd\u003e0.55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-1000 (385)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01°C (0.01°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu10.01 C\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003e0.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXK\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBP\u003c\/td\u003e\n\u003ctd\u003e1.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC Resolution\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRamp functions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamps\u003c\/td\u003e\n\u003ctd\u003eSlow ramp, Fast ramp, 25% step-ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLoop power function\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e22 mA, short circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStep functions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteps\u003c\/td\u003e\n\u003ctd\u003e25% of range, 100% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to +71°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010-1:1993, ANSI\/ISA S82.01-1994; CAN\/CSA C22.2 No 1010.1:1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e650 g (23 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery replacement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSeparate battery compartment, accessible without breaking calibration seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide port connections\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePressure module connector, also used for remote real-time programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899081810099,"sku":"1042806","price":9900.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a659f4ec-5f15-4ee3-9683-b108002bc6c0_product_slideshow_main2x.webp?v=1787724043"},{"product_id":"fluke-c125-meter-case-fluc125","title":"Fluke C125 Meter Case FLUC125","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZippered carrying case with detachable external pouch\u003c\/li\u003e\n\u003cli\u003eAccomodates Fluke 120 Series ScopeMeter Testtool or a handheld DMM, both main instrument and test accessories\u003c\/li\u003e\n\u003cli\u003eFront pouch can be detached for optimal flexibility\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge Case:\n\u003cul\u003e\n\u003cli\u003e10.0 × 5.25 × 2.0 inches\u003c\/li\u003e\n\u003cli\u003e54 × 133 × 51 millimetres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall Case:\n\u003cul\u003e\n\u003cli\u003e7.0 in × 5.5 in × 1.25 inches\u003c\/li\u003e\n\u003cli\u003e178 × 140 × 32 millimetres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Maximum Dimensions:\n\u003cul\u003e\n\u003cli\u003e10.0 in × 5.5 in × 3.25 inches\u003c\/li\u003e\n\u003cli\u003e254 × 140 × 83 millimetres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Products\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 87V MAX True-rms Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 28 II Rugged Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 27 II Rugged Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 177 True-RMS Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 179 True-RMS Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 179 IMSK Industrial Multimeter Service Kit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 175 True-RMS Digital Multimeter\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 87V MAX E2 Industrial Electrician Combo Kit\u003c\/li\u003e\n\u003cli\u003eFluke 725 Multifunction Process Calibrator\u003c\/li\u003e\n\u003cli\u003eFluke 789 ProcessMeter™\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke 787B ProcessMeter™\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899086069939,"sku":"1041459","price":139.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a3ed3911-c3bc-420a-a0fb-b108007b3f75_product_slideshow_main2x.webp?v=1787724577"},{"product_id":"fluke-networks-microscanner™-poe-cable-verifier-kit-ms-poe-kit","title":"Fluke Networks MicroScanner™ PoE Cable Verifier Kit MS-POE-KIT","description":"\u003cp\u003e\u003cspan\u003eThe MicroScanner PoE Cable Verifier validates and troubleshoots your Industrial Ethernet copper cabling, helping to reduce down time in time-sensitive industrial networks. It performs continuity tests on all wires in a few seconds and displays the results graphically, so you can see opens, shorts, and crossed wires.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe MicroScanner PoE helps make installation, maintenance, and troubleshooting on IT, security, PoE lighting, Ethernet-based HVAC devices, and IP-based building automation systems easier. Its oversized, backlit LCD screen displays clear results in any light or complete dark with intuitive icons and support of Class 0 to 8 PoE.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv id=\"fluke-product-display-features\"\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eReports PoE class (0-8), injector voltage, switch speed up to 10G\u003c\/li\u003e\n\u003cli\u003eShows wire map, length, cable ID, and distance to fault\u003c\/li\u003e\n\u003cli\u003eTrace cable or wire pairs with included IntelliTone™ Pro 200 probe\u003c\/li\u003e\n\u003cli\u003eIncludes Remote IDs to determine network layout quickly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpecifications apply at 23 °C (73 °F), unless otherwise noted.\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32 °F to 113 °F (0 °C to 45 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-4 °F to +140 °F (-20 °C to +60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (% RH without condensation)\u003c\/td\u003e\n\u003ctd\u003e90 % (50 °F to 95 °F 10 °C to 35 °C)\u003cbr\u003e75 % (95 °F to 113 °F 35 °C to 45 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and Vibration\u003c\/td\u003e\n\u003ctd\u003eRandom, 2 g, 5 Hz-500 Hz (Class 2)\u003cbr\u003e1 m drop test with and without wiremap adapter attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e4,000 m; Storage: 12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest connectors\u003c\/td\u003e\n\u003ctd\u003eShielded 8-pin modular jack accepts 8-pin modular (RJ45) and 4-pin modular (RJ11) plugs. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eBattery type: 2 AA (NEDA 15A, IEC LR6) alkaline batteries\u003cbr\u003eBattery life: 20 hours of typical use\u003cbr\u003eOther compatible battery types: 2 AA photo lithium, NIMH, NICAD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and weight (with batteries installed and wiremap adapter attached)\u003c\/td\u003e\n\u003ctd\u003e3 in x 6.4in x 1.4 in (7.6 cm x 16.3 cm x 3.6 cm)\u003cbr\u003eMicroScanner™ PoE: 10.6 oz (300 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMonochrome LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable test\u003c\/td\u003e\n\u003ctd\u003eMeasures length, verifies wiremap, identifies remote ID locators, and detects Ethernet ports. MicroScanner™ PoE also shows HIGH Ω when the resistance of the cable is more than 12.5 Ω. Displays results on one screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTone\u003c\/td\u003e\n\u003ctd\u003eGenerates Intellitone™ and normal analog toning signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eMicroScanner™ PoE: Solicits and detects the presence of 802.3af, at, bt, and UPOE (Cisco’s Universal Power over Ethernet) compatible PoE devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePerformance specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable types tested\u003c\/td\u003e\n\u003ctd\u003eTwisted pair: UTP, FTP, SSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength test\u003c\/td\u003e\n\u003ctd\u003eRange: 460 m (1500 ft)\u003cbr\u003eResolution: 0.3 m (1 ft)\u003cbr\u003eTypical accuracy: ± 4% or 0.6 m (2 ft) whichever is greater. NVP uncertainty is an additional error.\u003cbr\u003eCalibration: User-settable NVP for twisted pair and coax (MicroScanner™\u003csup\u003e2\u003c\/sup\u003e). Can determine actual NVP with known length of cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiremap test\u003c\/td\u003e\n\u003ctd\u003eDetects single-wire faults, shorts, miswires, split pairs, and up to seven far-end adapter IDs. The wiremap is drawn with proportional length to visually indicate the approximate location of faults.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet port detection\u003c\/td\u003e\n\u003ctd\u003eMicroScanner™ PoE: Detects the advertised speed of 802.3 Ethernet ports with speeds of 10 Mbps, 100 Mbps, 1 Gbps, 2.5 Gbps, 5 Gbps, and 10 Gbps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTone generator\u003c\/td\u003e\n\u003ctd\u003eSupports toning and cable mapping with a Fluke Networks digital IntelliTone™ probe. Generates four tones compatible with typical analog probes. SmartTone™ feature gives positive identification of cables in bundles when using an IntelliTone or an analog probe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899088953523,"sku":"8043035","price":2726.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/e6dc0264-779f-48bf-bc01-b108002f70d2_product_slideshow_main2x.webp?v=1787724882"},{"product_id":"fluke-1662-multifunction-tester-flu1662","title":"Fluke 1662 Multifunction Tester FLU1662","description":"\u003cp\u003eThe Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On\/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures RCD switching time and tripping level (ramp test)\u003c\/li\u003e\n\u003cli\u003eMeasures trip time and current for RCD type A \u0026amp; AC in one test\u003c\/li\u003e\n\u003cli\u003eMeasures RCD variable current\u003c\/li\u003e\n\u003cli\u003eProvides automatic RCD test sequence\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003eIncludes a phase sequence indicator\u003c\/li\u003e\n\u003cli\u003eComes with hard carrying case, padded carrying and waist strap, and remote control probe and lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAC voltage measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy 45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.8% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e360 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e660 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eContinuity testing (RLO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (autoranging)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation resistance measurement (RISO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy of test voltage (at rated test current)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+10%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 MΩ \/ 50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLoop and line impedance (ZI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eProspective earth fault current, PSC test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 A \/ 10 kA (50 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 A \/ 0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRCD testing, RCD types tested\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCD Type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA\u003csup\u003e4\u003c\/sup\u003e, AC¹, G², S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTripping speed test (ΔT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent settings¹\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplier\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003eRCD Type G\u003c\/td\u003e\n\u003ctd\u003e310 ms\u003cbr\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRCD Type S\u003c\/td\u003e\n\u003ctd\u003e510 ms\u003cbr\u003e160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30% to 110% of RCD rated current¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% of IΔN²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDwell time\u003c\/td\u003e\n\u003ctd\u003eType G\u003c\/td\u003e\n\u003ctd\u003e300 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType S\u003c\/td\u003e\n\u003ctd\u003e500 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified trip current ranges (EN 61008-1)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePhase Sequence Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcon\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\" alt=\"icon phase sequence indicator\" align=\"top\"\u003e\n\u003cp\u003e Phase Sequence indicator is active.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 x 25 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.3 (kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eType AA, 6 ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with EN\/IEC 61010-1 and  EN\/IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT III \/ 500V; CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN61557-1 to EN61557-7 and EN61557-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899091607731,"sku":"834120","price":2499.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/86db63f6-f9fb-44e9-8d75-b108002eb9c0_product_slideshow_main2x.webp?v=1787725334"},{"product_id":"fluke-789-processmeter™-flu789","title":"Fluke 789 ProcessMeter™ FLU789","description":"\u003cp\u003e\u003cstrong\u003eFluke 789 ProcessMeter™ doubles your troubleshooting power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a full-featured loop calibrator with the power of a CAT III 1000 V, CAT IV 600 V safety rated digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a large, dual display with two levels of backlighting and externally accessible fuse and batteries for easy replacement. And its built-in, selectable 250-ohm HART® resistor eliminates the need to carry a separate resistor.\u003c\/p\u003e\n\u003cp\u003eThe 789 also has a built-in 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can also add the wireless data logging capabilities of the Fluke Connect™ mobile app to log data wirelessly to your smart phone and review it from a remote location.\u003c\/p\u003e\n\u003cp\u003e*Requires Fluke IR3000FC module (not included). Not all models are available in all countries. Check with your local Fluke representative.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo a lot more while carrying a lot less\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 789 provides all standard DMM capabilities including frequency measurement to 20 kHz, Min\/Max\/Average\/Hold\/Relative modes, and diode test and continuity beeper. Combine that with the ability to troubleshoot every part of the loop.\u003c\/p\u003e\n\u003cp\u003eMeasure, source, simulate 4-20 mA signals, measure resistance, measure power, provide power to the loop and provide 250-ohm resistance to the loop. The 789 includes SpanCheck; 0% and 100% buttons to toggle between 4 and 20 mA sourcing, while the display can simultaneously show mA and % of scale readings for faster troubleshooting. It also delivers 1200-ohm drive capability on mA source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis ProcessMeter offers manual step, 100%, 25%, Coarse, Fine, plus auto step and auto ramp. It also delivers 0.1% DC voltage accuracy and 0.05% DC current accuracy.\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\" colspan=\"3\" style=\"width: 99.2844%;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 32.737%;\"\u003eDC measurement\u003c\/td\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0-1 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.2% + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.05% + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 32.737%;\"\u003eAC measurement\u003c\/td\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0-1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eAccuracy (25 Hz to 2 kHz)\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e+\/- 1% +2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 32.737%;\"\u003eCurrent sourcing\u003c\/td\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.05% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eDrive capability\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e24 V Compliance or 1200 Ω @ 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eContinuity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eBeeps for resistance \u0026lt; 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 32.737%;\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0-1000 V AC (true-rms) or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.1 mV to 1.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.3703%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 39.1771%;\"\u003e0.1% Rdg + 1 LSD (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eResistance measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eto 40 MΩ, 0.2% + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eDiode test\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e2.0 V shows diode voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eDisplay current and % of span\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eAuto Step, Auto Ramp\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.2844%;\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e95% up to 30°C\u003cbr\u003e75% up to 40°C\u003cbr\u003e45% up to 50°C\u003cbr\u003e35% up to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e0.05 x (specified accuracy) per °C (for temperatures \u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.2844%;\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eElectrical safety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eDesigned in accordance with IEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eIEC 61010-2-033: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e1,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 99.2844%;\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e610 g (1.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003e140 hours typical (measurement), 10 hours typical (sourcing 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.737%;\"\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 66.5474%;\"\u003eRandom, 2 g, 5-500 Hz\u003cbr\u003e1 meter drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899104846003,"sku":"1041174","price":2846.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/52ef16ff-4507-42ac-8d77-b108002bce14_product_slideshow_main2x.webp?v=1787725640"},{"product_id":"fluke-117-323-electricians-combo-kit-digital-multimeter-and-clamp-meter-flu117-323","title":"Fluke 117\/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter FLU117\/323","description":"\u003cp\u003eHaving the right tools for the job is essential. Having them when you need them is even better. Arrive on every jobsite prepared with the Fluke 117\/323 electricians multimeter and clamp meter combo kit. The two test tools give you the power of a versatile, rugged multimeter combined with a fast-acting, general-purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eWhether you work in residential electricity or commercial electrical, both of these test tools are a good fit for the work you need to complete. The kit includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 117 digital multimeter\u003c\/li\u003e\n\u003cli\u003eFluke 323 clamp meter\u003c\/li\u003e\n\u003cli\u003eTl175 test leads\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak magnetic meter hanger\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 117 digital multimeter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to make your life easier with features like:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eAutoV\/LoZ function\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average readings\u003c\/li\u003e\n\u003cli\u003eFrequency measurements\u003c\/li\u003e\n\u003cli\u003eCapacitance measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn order to ensure you’re ready to go on many jobsites, the 117 is certified for use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 323 clamp meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a good basic troubleshooting tool for commercial and residential electricians. It includes true rms measurements, optimized ergonomics and a large display for efficient troubleshooting. The small clamp is designed to make measurements in tight cable compartments easier on you and it’s ideally suited for current measurements up to 400 A or voltage measurements up to 600 V.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 117 Electrician’s Multimeter and 323 True-rms Clamp Meter give electricians easy to use, time-saving tools for your work.\u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003ch4\u003eFluke 117 Digital Multimeter\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse for A input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 A, 1000 V FAST Fuse (Fluke PN 803293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAccuracy Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC amps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.1 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC amps\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.1 A10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.99 Hz \/ 0.1 Hz\u003cbr\u003e9.999 Hz \/ 0.001 Hz\u003cbr\u003e50.00 Hz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFrequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003c\/li\u003e\n\u003cli\u003eTemperature Range\/Resolution: -40 °F to 752 °F \/ 0.2 °F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 323 True RMS Clamp Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ±5 digits\u003cbr\u003e(45 Hz to 65 Hz)\u003cbr\u003e2.5% ±5 digits\u003cbr\u003e(65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\/Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\/ 4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData hold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eH x W x D (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899160748211,"sku":"8730099","price":669.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/4e3f20e4-983a-45c1-8200-b31a011cf2c9_product_slideshow_main2x.webp?v=1787725924"},{"product_id":"fluke-88v-a-automotive-multimeter-combo-kit-flu88v-a-kit","title":"Fluke 88V\/A Automotive Multimeter Combo Kit FLU88V\/A-KIT","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eA complete automotive diagnostic package with everything you need in an automotive multimeter. Fluke 88V has replaced the 88.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 88V has improved measurement functions, troubleshooting features and accuracy to solve more problems on conventional and hybrid vehicles. The 88V is made in the U.S.A. and carries the industry leading lifetime warranty.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 88V operates very similar to the classic Fluke 88, but with more problem solving power, safety, convenience and impact protection.\u003c\/p\u003e\n\u003cp\u003eThe 88V is independently tested to comply with the 2nd edition of ANSI\/ISA S82.01 and EN61010-1 CAT IV 600 V\/CAT III 1000 V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLifetime warranty\u003c\/li\u003e\n\u003cli\u003e6000 counts, 3-3\/4 digits\u003c\/li\u003e\n\u003cli\u003eMeasure up to 1000 V AC and DC\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A, 20 A for up to 30 seconds\u003c\/li\u003e\n\u003cli\u003eBuilt in thermometer lets you carry one less tool (temperature probe included)\u003c\/li\u003e\n\u003cli\u003eFrequency to 200 kHz and % duty cycle\u003c\/li\u003e\n\u003cli\u003eResistance, continuity\u003c\/li\u003e\n\u003cli\u003eRPM measurements with inductive pickup\u003c\/li\u003e\n\u003cli\u003eMillisecond pulse width measurements for fuel injectors\u003c\/li\u003e\n\u003cli\u003eMagnet hanger to attach meter to the vehicle and free your hands for other tasks\u003c\/li\u003e\n\u003cli\u003e10,000 µF capacitance range for components and motor caps\u003c\/li\u003e\n\u003cli\u003eMin\/Max-Average recording with Min\/Max Alert to capture variations automatically\u003c\/li\u003e\n\u003cli\u003ePeak capture to record transients as fast as 250 µs\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead interference from low ohms measurements\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eTouch Hold to capture stable readings avoiding noisy signals\u003c\/li\u003e\n\u003cli\u003eLarge display digits and two-level bright white backlight for increased visibility\u003c\/li\u003e\n\u003cli\u003eAnalog bargraph for fast changing or unstable signals\u003c\/li\u003e\n\u003cli\u003eInput Alert provides audible warning against wrong use of input jacks\u003c\/li\u003e\n\u003cli\u003eImproved selectable sleep mode for long battery life\u003c\/li\u003e\n\u003cli\u003eAccess door for fast battery changes without opening up the case\u003c\/li\u003e\n\u003cli\u003e\"Classic\" design with new removable holster with built in test lead and probe storage\u003c\/li\u003e\n\u003cli\u003e10 meg ohm input impedance wont load circuits\u003c\/li\u003e\n\u003cli\u003e0.1% DC accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePosition the meter in the most usable location with the magnetic hanger\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe holster on the new Fluke 88V accepts a small but extremely powerful magnet (Fluke Tpak) that holds the meter firmly to most steel surfaces. This allows you to focus on taking measurements instead of holding the meter in your hand.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll inputs are protected to Category III, 1000 V and Category IV 600 V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDCV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eACV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Bandwidth\u003c\/td\u003e\n\u003ctd\u003e5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.4% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.4% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 KHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Duty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003ewithin 2% per KHz +0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200.0°C - 1090°C\u003cbr\u003e-328.0°F - 1994.0°F, 1.0% excluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK Temperature Probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C - 260°C\u003cbr\u003e-40°F - 500°F, 2.2°C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C - 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C - 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.2 x 9.8 x 20.1 cm (2.06 x 3.86 x 7.93 in)\u003cbr\u003e624 g (22 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899203182771,"sku":"8730100","price":1529.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/e61fff20-72b2-4d46-882c-b108006a5364_product_slideshow_main2x.webp?v=1787726215"}],"url":"https:\/\/beyondtools.com\/en-gb\/collections\/fluke.oembed?page=4","provider":"Beyond Tools","version":"1.0","type":"link"}