{"product_id":"fluke-726-precision-multifunction-calibrator-flu726","title":"Fluke 726 Precision Multifunction Calibrator FLU726","description":"\u003cp\u003e\u003cstrong\u003eProcess calibration designed specifically for process industries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and\/or sources pressure using when paired with any of the 50\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-750p\"\u003eFluke 750P series Pressure Modules\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eto test and calibrate pressure transmitters and other devices. The 726 can also:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSource mA with simultaneous pressure measurement to conduct valve and I\/P test\u003c\/li\u003e\n\u003cli\u003eConduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for ease of use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.\u003c\/p\u003e\n\u003cp\u003eYou can also use the 726 to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCapture the set, reset, and deadband of a pressure switch with the integrated switch test\u003c\/li\u003e\n\u003cli\u003eCalculate the transmitter error % to interpret calibration results without the use of a calculator\u003c\/li\u003e\n\u003cli\u003ePerform fast linearity tests with the auto-step and auto-ramp features\u003c\/li\u003e\n\u003cli\u003ePower a transmitter during test using 24 V loop supply and simultaneous mA measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you want documenting and HART communication built into your calibrator, consider the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/multifunction-calibrators\/fluke-754\"\u003eFluke 754 Documenting Process Calibrator with HART\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"25%\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30.000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (upper display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (lower display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24.000 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%+ 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.0 to 4000.0 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.00 to 15.00 kHz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e1 V peak-to-peak-minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSource Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100.00 mV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24.000 mA (Source)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24.000 mA (Simulate)\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResistance\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cstrong\u003eRange, accuracy (percent of reading + floor) and excitation current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 to 1000.0 CPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 10.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 to 15.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003e5 V p-p squarewave, -0.1 V offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eRTDs and Thermocouples\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"23\"\u003eMeasure and source accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCu10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNI-120\u003c\/td\u003e\n\u003ctd\u003e0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (385)\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (392)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (391-JIS)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-200 (385)\u003c\/td\u003e\n\u003ctd\u003e0.95°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-500 (385)\u003c\/td\u003e\n\u003ctd\u003e0.55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-1000 (385)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01°C (0.01°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu10.01 C\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003e0.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXK\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBP\u003c\/td\u003e\n\u003ctd\u003e1.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC Resolution\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRamp functions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamps\u003c\/td\u003e\n\u003ctd\u003eSlow ramp, Fast ramp, 25% step-ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLoop power function\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e22 mA, short circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStep functions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSource functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, resistance, frequency, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteps\u003c\/td\u003e\n\u003ctd\u003e25% of range, 100% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to +71°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010-1:1993, ANSI\/ISA S82.01-1994; CAN\/CSA C22.2 No 1010.1:1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e650 g (23 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery replacement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSeparate battery compartment, accessible without breaking calibration seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide port connections\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePressure module connector, also used for remote real-time programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899081810099,"sku":"1042806","price":5321.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/a659f4ec-5f15-4ee3-9683-b108002bc6c0_product_slideshow_main2x.webp?v=1787724043","url":"https:\/\/beyondtools.com\/en-gb\/products\/fluke-726-precision-multifunction-calibrator-flu726","provider":"Beyond Tools","version":"1.0","type":"link"}