{"product_id":"fluke-8808a-digital-multimeter-flu8808a","title":"Fluke 8808A Digital Multimeter FLU8808A","description":"\u003cp\u003eThe Fluke 8808A multimeter has a broad range of functions, measuring volts, ohms and amps with a basic V DC accuracy of 0.015%. It is remarkably easy to use, even by unskilled operators, because it makes the measurements you perform most often extremely easy and fast to do.\u003c\/p\u003e\n\u003cp\u003eSix setup buttons on the 8808A front panel operate like a car radio’s station presets. Simply set up the meter for a common measurement, then press shift followed by a setup button (S1 to S6) to save the setup. Now each time you perform that measurement, you simply press the appropriate setup key. It’s that easy!\u003c\/p\u003e\n\u003cp\u003eThe setup buttons eliminate the need to follow complex work instruction sheets. Operators no longer need to press multiple buttons to set up a measurement function and range, test limits, or enter other parameters to make a measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate production mistakes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 8808A 5.5 digit multimeter dependably performs the most common measurements required by today’s applications. Whether you are performing functional tests or making critical measurements on test points, using the limit compare mode with pass\/fail indicators eliminates production mistakes, especially those where results are “on the edge.” The 8808A display has built-in enunciators that clearly show the operator whether a test passes or fails. The pass\/fail indicators take the guesswork out of testing: the result is either within limits or it’s out!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImprove quality and efficiency in manufacturing test, R\u0026amp;D or service applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturing test, R\u0026amp;D, development and service applications demand performance and flexibility from a bench meter. This Fluke 8808A makes measurements that stand up to any scrutiny. It delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency—all at superior accuracy and resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure two parameters at once\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8808A features a unique dual display that allows you to measure two different parameters of the same signal from one test connection. Looking at dual interrelated parameters like voltage and current simultaneously can reveal conditions that might go unnoticed otherwise, greatly simplifying test and troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure sensitive leakage current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypical multimeters use a shunt method to measure current, creating a measurement burden voltage that increases the error in low current measurements. This makes it difficult, if not impossible, to perform tasks such as determining the true leakage current on a battery-powered device while it is powered down, or measuring small currents in sensitive circuits. The Fluke 8808A is the only multimeter in its class to use a low-impedance operational amplifier and current-to-voltage conversion technique to eliminate the burden voltage and measure sensitive low currents. In this special mode, the 8808A can accurately measure small currents with a resolution of up to 100 nA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerform 4-wire measurements with only two leads\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePatented split terminal jacks for the 2x4-wire ohms function allow you to perform 4-wire measurements using only two leads instead of four. Today’s surface mount components make it difficult to make connections. The task becomes even more difficult when you need to use a 4-wire technique for accurate low ohms measurements. The Fluke test lead accessory combines the four wires into two test lead pairs, making it easy for you to establish connections. You get excellent resolution and accuracy, plus the convenience and ease of using a single pair of leads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlukeView® Forms Basic\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze individual readings or series of measurements, then convert them into professional looking documents. Transfer data points from your meter to your PC and use the standard, non-customizable forms to display your readings in table or graphical form. For a larger array of forms or to use FlukeView® Forms Designer customize your forms, upgrade to FlukeView® Forms 3.0 with FVF-UG.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke quality is built in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke is known around the world for its rugged, reliable, and accurate multimeters. With our experience, design standards and quality assurance processes, we have designed a multimeter that will stand up to any scrutiny of its specifications. In fact, a Fluke meter typically performs better than specified. All of our efforts are designed to ensure that you can make an accurate measurement— repeatedly, and with confidence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVFD multi segment display, dual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eV DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 uV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.015 + 0.003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eV AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mV to 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 uV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2 + 0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e20 Hz to 100 KHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 x 4 Wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200 Ω to 100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.02 + 0.003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eA DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 µA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e1 nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.02 + 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eA AC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e100 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.3 + 0.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e20 Hz to 2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Hz to 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMath functions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003edB\/dBm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLimit compare test, with pass and fail indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS-232, USB with optional adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming languages\/modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSimplified ASCII, Fluke 45 remote command emulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 kg (4.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e88 x 217 x 297 mm (3.46 x 8.56 x 11.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDesigned to comply with EN 61010-1:2001, ANSI\/ISA 61010-1 (S82.02.01):2004, UL 61010-1:2004, AN\/CSA C22.2 No. 61010.1:2004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration documentation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStatement of calibration practices included; calibration report optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45899283202227,"sku":"1042776","price":2200.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/3160\/1843\/files\/152e13d2-6f83-4db8-aa0b-b108002bd768_product_slideshow_main2x.webp?v=1787726665","url":"https:\/\/beyondtools.com\/products\/fluke-8808a-digital-multimeter-flu8808a","provider":"Beyond Tools","version":"1.0","type":"link"}