Installation Multifunction Tester 1663FVS by Fluke

FlukeSKU: 1000366

Price:
Sale price$3,549.70

Tax included Shipping calculated at checkout

Stock:
Re-stocking soon

Pickup available at 23 Exhibition Drive

Usually ready in 24 hours

CLICK HERE to Shop our Sale!

Description

Features

  • Full featured tester for installation professionals
  • Tests to all local regulations and provides test results for complete documentation
  • Tests continuity at L-N, N-PE inputs
  • Tests smooth dc sensitive RCDs (Type B)
  • Tests earth resistance, voltage, and frequency
  • Offers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

    Fluke 1663 Multifunction Installation Tester is the ideal choice for hard working professionals

    The 1663 installation tester delivers the full-featured functionality and advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. Operation is intuitive and easily mastered by all levels of workers so you can put it to work immediately for quick and efficient testing to all local regulations. Additional helpful features like On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.

    Other useful capabilities:

    • Checks wiring polarity to detect broken N wires
    • Measures insulation resistance and loop and line resistance
    • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
    • Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
    • Measures motor windings with continuity test
    • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
    • Measures RCD switching time and tripping level (ramp test)
    • Measures trip time and current for RCD type A & AC in one test
    • Measures RCD variable current
    • Provides automatic RCD test sequence
    • Includes a phase sequence indicator
    • Safety rated CAT III 500V, CAT IV 300V
    • Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead

    Specifications: Fluke 1663 Multifunction Testers:

    AC voltage measurement
    Range 500 V
    Resolution 0.1 V
    Accuracy 45 Hz – 66 Hz 0.8% + 3
    Input impedance 360 kΩ
    Overload protection 660 V rms
    Continuity testing (RLO)
    Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
    Resolution 0.01 Ω / 0.1 Ω / 1 Ω
    Open Circuit Voltage >4 V
    Insulation resistance measurement (RISO)
    Test voltages 50-100-250-500-1000 V
    Accuracy of tTest voltage (at rated test current) +10%, -0%
    Test voltage 50 V
    100 V
    250 V
    500 V
    1000 V
    Insulation resistance range 20 MΩ /50 MΩ
    20 MΩ / 100 MΩ
    20 MΩ / 200 MΩ
    20 MΩ / 200 MΩ / 500 MΩ
    20 MΩ / 200 MΩ / 1000 MΩ
    Resolution 0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ / 1 MΩ
    0.01 MΩ / 0.1 MΩ / 1 MΩ
    Test current 1 mA @ 50 kΩ
    1 mA @ 100 kΩ
    1 mA @ 250 kΩ
    1 mA @ 500 kΩ
    1 mA @ 1 MΩ
    Loop and line impedance (ZI)
    Range 10 Ω / 0.001 Ω / High current mΩ mode
    Resolution 0.01 Ω / 0.1 Ω / 1 Ω
    Prospective earth fault current, PSC test
    Range 1000 A / 10 kA (50 kA)
    Resolution 1 A / 0.1 kA
    Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
    RCD testing, RCD types tested
    RCD Type AC¹
    G²,S³
    Model 1663 A4, AC¹, G²,S³
    Notes ¹Responds to AC
    ²General, no delay
    ³Time delay
    4Responds to pulsed signal
    5Responds to smooth DC signal
    Tripping speed test (ΔT)
    Current settings¹ 10-30-100-300-500-1000 mA – VAR
    10-30-100 mA
    Multiplier x ½, x 1
    x 5
    Measurement range RCD Type G 310 ms
    50 ms
    RCD Type S 510 ms
    160 ms
    Notes ¹1000 mA type AC only
    700 mA maximum type A in VAR mode
    VAR mode not available for type B.
    RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
    Current range 30% to 110% of RCD rated current¹
    Step size 10% of IΔN²
    Dwell time Type G 300 ms/step
    Type S 500 ms/step
    Measurement accuracy ±5%
    Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC
    35% to 140% for Type A (>10 mA)
    35% to 200% for Type A (≤10 mA)
    50% to 200% for Type B
    ²5% for Type B
    Notes ¹30% to 150% for Type A IΔN > 10 mA
    30% to 210% for Type A IΔN = 10 mA
    20% to 210% for Type B
    Earth Resistance Test (RE)
    Range 200 Ω / 2000 Ω
    Resolution 0.1 Ω / 1Ω
    Frequency 128 Hz
    Output Voltage 25 V
    Phase Sequence Indication
    Icon icon phase sequence indicator Phase Sequence indicator is active.
    General Specifications
    Size (L x W x H) 10 x 25 x 12.5 cm
    Weight (incl. batteries) 1.3 Kg
    Battery size, quantity Type AA, 6 ea.
    Sealing IP-40
    Safety Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034
    Overvoltage CAT III / 500V; CAT IV 300V
    Performance EN61557-1 to EN61557-7 and EN61557-10

      Additional Information

      Installation Multifunction Tester 1663FVS by Fluke
      $3,549.70

      Optional Accessories

      Payment & Security

      American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

      Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

      hidden

      You may also like

      Recently viewed